EN - 19
MIG/MAG ROBO welding torch
10 Troubleshooting
9.4 Cleaning the wire guide
1
Unscrew the cable assembly on the machine side and lay it out in a
stretched position.
2
Unscrew the nut and pull out the liner.
3
Clean the wire conduit from both sides with compressed air.
4
Slide the adjusted liner into the wire conduit and secure with a nut.
9.5 Cleaning the torch neck
To increase the system availability of the welding robot,
ABICOR BINZEL
offers automated torch cleaning.
1
Remove the gas nozzle.
2
Remove the welding spatter and spray with
ABICOR BINZEL
anti-spatter
fluid.
3
Check the wear parts for visible damage and replace them if necessary.
4
Replace the equipment kit when worn or soiled.
5
Clean the separating point and O-rings with silicone-free seal grease.
6
Test the TCP in the alignment jig after every use or following a collision.
10 Troubleshooting
Please observe the attached document "Warranty". In the event of any doubts
and/or problems, please contact your retailer or the manufacturer.
WARNING
Risk of injury
Serious injuries caused by parts swirling around.
• When cleaning the wire guide with compressed air, always wear
personal protective clothing, in particular safety goggles.
DANGER
Risk of injury and machine damage when handled by
unauthorised persons
Improper repair work and modifications to the product may lead to serious
injuries and damage to the device. The product warranty will be rendered
invalid if the unit is handled by unauthorised persons.
• Operating, maintenance, cleaning, fault and repair work may only be
carried out by qualified personnel (in Germany see TRBS 1203).