F45/F46/F47: Special end crater filling sequence
(Effective/Standard)
Enables the time for start and end crater current to be set. Turning on the F45 function allows the weld
start/end crater filling (set by the F46/F47 functions) to be executed.
When the function is activated, the LED above the <Operating mode> selection button blinks and the
F46/F47 functions are available. Internal function F46 is used to set the time for the weld start in the range
of 0.0 to 10.0 seconds.
The internal function F47 sets the time for the end crater filling in the range of 0.0 to 10.0 seconds.
Adjustable range
ON/OFF
Default value
OFF
Storage option
Yes
Description
F45: Sets the start and end crater filling parameters for a set period
of time.
OFF: inactive
ON: parameters from F46 and F47 are used
Adjustable range
0 to 10 s
Default value
0 s
Storage option
Yes
Description
F46: Defines the time of the starting current.
(Active if F45 is set to ON.)
Adjustable range
0 to 10 s
Default value
0 s
Storage option
Yes
Description
F47: Defines the end crater filling time. (Active if F45 is set to ON.)
ON
OFF
Wire feed speed
Output voltage
Gas flow
Start signal
Welding current
End crater filling flow
Backburn time
Gas post flows
Welding current
Starting current
End crater
filling
Main welding parameter
Start
parameter
Gas pre-flows
Idle voltage
Creep speed
Set time via F46
Set time via F47