D
Welding wire is not
correctly fed
• Wire conduit coil is soiled
• Disassemble wire conduit coil
and air-blast with compressed air
• Wear safety goggles
9 Maintenance and cleaning
on page EN-19
• Wire conduit coil worn
• Replace wire conduit coil
• Wire conduit coil cut to short
• Mount new wire conduit coil
• Wire guide soiled by wire wear
(model with wire brake)
• Disassemble wire guide and air-
blast with compressed air.
• Wear safety goggles
9 Maintenance and cleaning
on page EN-19
Fault
Cause
Troubleshooting
Tab. 11
Troubleshooting
DANGER
Risk of injury due to unexpected start
The following instructions must be followed during all maintenance,
servicing, disassembly and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and
damage.
• Replace any damaged, deformed or worn parts.