EN - 22
7 Operation
ABIPLAS
®
WELD CT Plasma drive
The high-frequency ignition aid will be switched off automatically after igniting
the arc.
3
Position welding torch close above the work-piece. Keep the distance
between work-piece and gas nozzle at about 5 mm.
4
Ignite the main arc.
5
Start the welding process.
The plasma welding torch is running.
7.1 Operating elements
1
Inching trigger
2
Inching reverse trigger
3
Gas test trigger
4
CAT socket
Fig. 13
Operating elements
CAT
1
2
3
4
Symbol
Designation
. To feed in wire.
WARNING
Danger of crushing
Limbs can be drawn in and crushed.
• Do not reach into the danger zone.
Symbol
Designation
Inching reverse trigger
. Setup function only, in order to position the wire end correctly.
NOTE
• Press the Inching Reverse trigger
only for feeding wire by a few
millimeters. In case of non-observance, compressions and feeding
problems cannot be excluded!