EN - 23
ABIPLAS
®
WELD CT Plasma drive
8 Putting out of operation
8 Putting out of operation
1
Switch off main current and pilot current.
2
Switch off the power supply.
3
Close the shut-off valves for the gas supply.
9 Maintenance and cleaning
Scheduled maintenance and cleaning is a prerequisite for a long life and a
trouble-free operation.
Symbol
Designation
Gas test trigger
. To check the gas volume or measurements.
. The EMERGENCY STOP safety switch-off of the CAT torch mount is
connected to this socket via a spiral cable and passed on by the integrated control to the
peripheral devices power supply, robot control system and wire feeder.
CAT
NOTE
• As the
ABIPLAS
®
WELD CT
Plasma drive
is integrated into a
welding system, putting out of operation depends on the robot control
system. Please make sure that the shutdown procedures for all
components integrated in the welding system are strictly observed.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Close off the gas supply.
• Close off the compressed air supply.
• Pull the mains plug.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.