This menu allows you to change all the parameters that
regulate the movement of the engines.
- RELEASED MECHANICS: NO: the reducer is not unlockable
YES: the reducer is unlockable
- PAUSE TIME: Allows you to adjust the PAUSE time after
which the automation closes automatically.
- MOVE MOTOR 1: Allows motor 1 to be moved to test the
motor or position it in the desired position
- MOVE MOTOR 2: Allows motor 2 to be moved to test the
motor or position it in the desired position
- PEDESTRIAN PERCENTAGE: It allows to adjust the
PEDESTRIAN OPENING percentage
Press the [>] key until you reach the <RADIO> menu and
then press [OK].
Press the key of the radio control that you want to insert in
the memory as START.
Operating logic selection
Press the [>] key until you reach the <LOGIC> menu and
then press [OK].
Select the logic you prefer:
- STEP-BY-STEP: when the barrier is closed, a START
opens, during the opening phase, a START stops the
barrier and another START closes, with the barrier open, a
START closes, during the closing phase one START stops
the barrier and an additional START opens.
- AUTOMATIC: when the gate is closed, a START opens,
during the opening phase, a START stops the barrier and
another START closes.
During the pause a START closes, the darkening of the
photocells recharges the pause time, at the end of the
pause the barrier closes automatically.
During the closing phase one START stops the barrier and
another START opens.
- AUTOMATIC WITH ANTICIPABLE CLOSING: when the
barrier is closed, a START opens, during the opening
phase, a START stops the barrier and another START
closes.
During the pause a START closes, the blackout of the
photocell FT2 recharges the pause time, the passage in
front of the photocell FT1 anticipates the reclosing, at the
end of the pause the barrier closes automatically.
During the closing phase one START stops the barrier and
another START opens.
- CONDOMINIUM: when the barrier is closed, a START
opens, during the opening phase the STARTs are ignored.
During the pause, a START and the darkening of the
photocells recharge the pause time, at the end of the
pause the barrier closes automatically.
During the closing phase one START stops the barrier and
another START opens.
- CONDOMINIUM WITH ANTICIPABLE CLOSING:
when the barrier is closed, a START opens, during the
opening phase the STARTs are ignored. During the pause,
a START and the darkening of the photocells recharge the
pause time, the passage in front of the photocell FT1
anticipates the closing, at the end of the break the barrier
closes automatically.
During the closing phase one START stops the barrier and
another START opens.
Entering the radio code START
Run programming
Press the [>] key until you reach the [PROGRAM] menu
and press [OK].
The display shows: GATE CLOSED?
If the barrier is in closed position press [OK], otherwise
press [CANC],
Now press the START button on the remote control.
The motors will push against the closing stop for a few
seconds, after which the barrier will begin to open.
Wait for the barrier to reach the fully open position.
Now the barrier restarts at full speed.
The barrier reaches the position of complete closure.
The programming is terminated.
Press [OK] to exit the programming procedure.
Press the START button again, the barrier will perform a
small closing movement.
Now the barrier is in normal operation.
Speed Change
Press the [>] key until you reach the <POWER> menu and
then press [OK].
Select the desired force and press [OK] again.
Change pause time
Press the [>] button until you reach the <PAUSE TIME>
menu and then press [OK].
Use the [>] and [<] keys to change the pause time for
which the automation remains open before closing in
AUTOMATIC or CONDOMINIUM logic.
Press [OK]
Motors
Advanced settings
Radio codes
Press the [>] key until you reach the [Setup Advanced]
and then press [OK].
Now enter the password and press [OK].
Using the [RADIO] menu it is possible to program the
following codes:
- START: START command from radio control
- STOP: STOP command from the remote control
- OPEN: command OPEN by radio control
- CLOSE: CLOSE command from the radio control
- PEDESTRIAN START: pedestrian opening command of the
engine 1
- AUX COMMAND: commands the AUX output to be
- DEAD MAN OPENING: the command opens the
automation ignoring safeties (photocells) and obstacle
detection (it is necessary to keep the button pressed for
the entire duration of the maneuver)
- DEAD MAN CLOSING: the command closes the
automation ignoring safety devices (photocells) and
obstacle detection (it is necessary to keep the key pressed
for the entire duration of the maneuver)
It is also possible to remove a single radio code or all radio
codes.
6