CN3-BT control unit
< R A D I O >
E N T E R ( O K )
< L O G I C >
E N T E R ( O K )
< P O W E R >
E N T E R ( O K )
< P A U S E T I M E >
E N T E R ( O K )
< P R O G R A M >
E N T E R ( O K )
< S E T T I N G S >
E N T E R ( O K )
< T I M E R >
E N T E R ( O K )
Q 1 2 2 3 Q 2 6 1 8
I N ^ ^ ^ ^ F ^ ^ S ^ ^ ^ O K !
M O D I F Y L A N G U A G E
[ O K ]
OK
>
>
CANC
>+
-<
Press the> + key to move to the next menu
Press OK and then press the key of the remote control you want to program
Press OK and select the logic you want
Press OK and select the time for which the gate must be open in
AUTOMATIC or CONDOMINIUM logic
Press OK and select the gate strength.
Press OK to enter the run programming procedure (the kits are supplied
already programmed)
Press OK to change the timer
Press OK to change the language.
Press OK and enter the password (request it by phone or by mail) to enter
the advanced menu
Q 1 2 2 3 Q 2 6 1 8
I N ^ ^ ^ ^ F ^ ^ S ^ ^ ^ O K !
ERROR
OK : no error
STP : Stop
FT1 : Photocell 1
FT2 : Photocell 2
OC1 : Obstacle current motor 1
OC2 : Obstacle current motor 2
OE1 : Obstacle encoder motor 1
OE2 : Obstacle encoder motor 2
DR1 : Overcurrent motor 1
DR2 : Overcurrent motor 2
ZC1 : No currento motor 1
ZC2 : No currento motor 2
VDW : Voltage too low.
2.1 MENU “STATUS” :
Q1 : Motor 1 position
Q2 : Motor 2 position
Limitswitch C1/Encoder1
Limitswitch A1/Encoder2
Limitswitch C2
Limitswitch A2
Photocell1
Photocell2
Stop
Start1
Start2
^
_
X
Contact is closed
Contact is opened
Contact is deactivated
( see paragraph 9. )