RHD8000 / RHD16000 (Contrac)
ELECTRICAL ROTARY ACTUATOR | OI/RHD8000/16000-EN REV. D
13
Installation with additional output elements
When mounting an additional drive element instead of the
standard lever, the following installation conditions must be
observed:
Maximum permissible shaft loads
Type
radial force at
distance x
N (lbf)
Distance x
from shaft
edge
mm (in)
axial force
N (lbf)
Max. output
torque
RHD(E)8000
28284 (6358)
103 (4.04)
4911 (1104) Occasionally, 2
times nominal
torque for a
short time
RHD(E)16000
45255 (10173)
103 (4.04)
7858 (1767)
M10347
X
F
R
Figure 5: Shaft end
Configuring the drive element hub
The new output element is mechanically connected to the
actuator shaft via a hole with feather key groove. This
connection should be designed so that the nominal torque and
any possible max. output torque is transmitted securely. The
drive element must be mounted securely on the output drive
shaft with suitable measures to prevent axial shift. For the new
drive element, you can use the current mechanical stops.
The following parameters must be observed:
Type bore
diameter
mm (in)
Feather key width
mm (in)
Hub length
mm (in)
RHD(E)8000 110
+0.09/+0,036
(4.33
+0.00354/+0.00142
)
28
-0.022/-0,074
(1.1023 -
0.00087/-0.00291
)
205 (8.07)
RHD(E)16000 120
+0.09/+0,036
(4.73
+0.00354/+0.00142
)
32
-0.026/-0,088
(1.2599
-0.001023/
-0.003464
)
205 (8.07)
Minimum yield strength of the hub Rp 0.2 with actuator
RHD(E)8000 320 N/mm
2
(46412.80 lbf/in
2
).
Minimum yield strength of the hub Rp 0.2 with actuator
RHD(E)16000 250 N/mm
2
(36260.00 lbf/in
2
).
Change from two to one column