background image

 

 

 

List of related manuals 

All the documents available for the drive system DCS880 are listed below: 

General

 

Publication number 

EN  DE  IT  ES  FR  PL  ZH  RU 

DCS880 Quick guide

 

3ADW000545 

EN

 

DE

 

IT

 

ES

 

FR

   

 

 

Safety instructions all languages 

3ADW000481 

EN

 

DE

 

IT

 

ES

 

FR

 

PL

 

ZH

 

RU

 

DCS880 Manual set  

 

DCS880  
Manual set 

EN

   

 

 

 

 

 

 

DCS880 Units 

 

 

 

 

 

 

 

 

 

DCS880 Flyer 

3ADW000475 

EN

 

DE

 

IT

 

ES

 

FR

   

ZH

 

RU

 

DCS880 Technical catalog 

3ADW000465 

EN

 

DE

 

IT

 

ES

 

FR

 

PL

 

ZH

 

RU

 

DCS880 Hardware manual 

3ADW000462 

EN

 

DE

 

IT

 

ES

 

FR

 

PL

   

RU

 

DCS880 Firmware manual 

3ADW000474 

EN

   

IT

 

ES

 

FR

 

PL

   

RU

 

DCS880 Service manual  

3ADW000488 

EN

   

 

 

 

 

 

 

DCS880 Hardparallel manual 

3ADW000530 

EN   

 

 

 

 

 

 

DCS880 12-pulse manual 

3ADW000533 

EN

   

 

 

 

 

 

 

Instructions for mounting the SDCS-CMA-2 

3ADW000396 

EN

   

 

 

 

 

 

 

ACS-AP-x assistant control panels user’s manual  

3AUA0000085685 

EN

   

 

 

 

 

 

 

DCS Thyristor power converter – Technical guide  

3ADW000163 

EN

   

 

 

 

 

 

 

Functional safety 

 

 

 

 

 

 

 

 

 

Supplement for functional safety 

3ADW000452 

EN

   

IT

 

ES

 

FR

 

PL

   

RU

 

Functional safety for enclosed converter 

 

 

 

 

 

 

 

 

 

+Q957 Prevention of unexpected Start Up 

3ADW000504 

EN

   

 

 

 

 

 

 

+Q951 Emergency stop, category 0 with MC opening 

3ADW000505 

EN

   

 

 

 

 

 

 

+Q952 Emergency stop, category 1 with MC opening 

3ADW000506 

EN

   

 

 

 

 

 

 

+Q963 Emergency stop, category 0 without MC opening  3ADW000507 

EN

   

 

 

 

 

 

 

+Q964 Emergency stop, category 1 without MC opening  3ADW000508 

EN

   

 

 

 

 

 

 

Enclosed converter 

 

 

 

 

 

 

 

 

 

DCS800-A Installation manual 

3ADW000352 

EN

 

DE

   

 

 

 

 

 

DCS800-A +S880 Enclosed converters, flyer 

3ADW000523 

EN

   

 

 

 

 

 

 

Door mounting kits 

 

 

 

 

 

 

 

 

 

DPMP-01 mounting platform for ACS-AP control panel 

3AUA0000100140 

EN

   

 

 

 

 

 

 

DPMP-02 mounting platform for ACS-AP control panel 

3AUA0000136205 

EN

   

 

 

 

 

 

 

Serial communication 

 

 

 

 

 

 

 

 

 

FCAN-01 CANopen adapter module 

3AFE68615500 

EN

 

DE

   

 

 

 

 

 

FDNA-01 DeviceNet™ adapter module 

3AFE68573360 

EN

   

 

 

 

 

 

 

FECA-01 EtherCAT adapter module 

3AUA0000068940 

EN

 

DE

   

ES

   

 

 

 

FENA-11/-21 Ethernet adapter module 

3AUA0000093568 

EN

   

 

 

 

 

ZH

   

FEPL-02 Ethernet POWERLINK adapter module 

3AUA0000123527 

EN

 

DE

   

 

 

 

 

 

FPBA-01 PROFIBUS DP adapter module 

3AFE68573271 

EN

 

DE

   

 

 

PL

 

ZH

   

FSCA-01 RS-485 adapter module 

3AUA0000109533 

EN

   

 

 

 

 

ZH

   

FDCO-01/02 DDCS communication modules 

3AUA0000114058 

EN

   

 

 

 

 

 

 

Tool and maintenance manuals and guides

 

 

 

 

 

 

 

 

 

 

Drive composer PC tool

 

3AUA0000094606 

EN

   

 

 

 

 

 

 

Drive application programming (IEC61131-3) manual 

3AUA0000127808 

EN

   

 

 

 

 

 

 

Adaptive programming, Application guide 

3AXD50000028574 

EN

   

 

 

 

 

 

 

NETA-21 remote monitoring tool 

3AUA0000096939 

EN

   

 

 

 

 

 

 

NETA-21 remote monitoring tool guide 

3AUA0000096881 

EN

   

 

 

 

 

 

 

DDCS branching unit NDBU-95 user’s manual 

3BFE64285513 

EN

   

 

 

 

 

 

 

Extension modules 

 

 

 

 

 

 

 

 

 

FIO-11 Analog extension module  

3AFE68784930 

EN  DE

 

IT

   

 

 

 

 

FIO-01 Digital extension module 

3AFE68784921 

EN  DE

 

IT

   

 

 

 

 

FAIO-01 Analog extension module 

3AUA0000124968 

EN  DE

   

 

 

 

 

 

FDIO-01 Digital extension module 

3AUA0000124966 

EN 

 

 

 

 

 

 

 

FEN-01 TTL encoder interface 

3AFE68784603 

EN  DE

 

IT

   

 

 

ZH

   

FEN-31 HTL encoder interface 

3AUA0000031044 

EN 

 

 

 

 

 

ZH

   

FEA-03 F series extension adapter 

3AUA0000115811 

EN 

 

 

 

 

 

 

 

Ethernet tool network for ACS880 drives appl. guide 

3AUA0000125635 

EN 

 

 

 

 

 

 

 

Status 01.2020 

DCS880 Manuals list m en.docx 

 

Summary of Contents for +Q951

Page 1: ...nual Emergency stop stop category 1 without opening mains contactor option Q964 for DCS8x0 A cabinet drives equipped with DCS880 modules Individual E Stop E Stop cat 0 E Stop cat 1 POUS forced MC open...

Page 2: ...Enclosed converters flyer 3ADW000523 EN Door mounting kits DPMP 01 mounting platform for ACS AP control panel 3AUA0000100140 EN DPMP 02 mounting platform for ACS AP control panel 3AUA0000136205 EN Ser...

Page 3: ...gs 12 Hardware settings 13 Wiring 14 Q964 Start up and acceptance test 15 Use of the safety function 16 Activating 16 Resetting 16 Emergency stop indications 16 Q964 Fault tracing 17 Q964 Maintenance...

Page 4: ...at there is no dangerous voltage present WARNING After making additions to the drive safety circuit or modifying it or changing circuit boards inside the drive always test the functioning of the safet...

Page 5: ...s contactor breaker of the drive is opened Target audience The manual is intended for people who install start up use and service the safety option of the drive Read the manual before working on the d...

Page 6: ...e types HFT Hardware fault tolerance IEC 61508 EN IEC 62061 PFH Probability of dangerous failures per hour IEC 61508 EN ISO 13849 1 EN IEC 62061 EN IEC 61800 5 2 PL Performance level levels are a b c...

Page 7: ...he safety requirements Design the safety system The part of the design made by ABB is described in chapter Option description and instructions on page 8 If you made any changes to the delivered safety...

Page 8: ...motor s The mains contactor breaker of the drive is not opened For a detailed description of the Safe torque off function see the appropriate hardware manual The SS1 and STO functions comply with EN...

Page 9: ...or A41 Drive Control board P62 Emergency stop indication lamp A61 Emergency stop safety relay S61 Emergency stop button K61 Timer relay OFF3 ACK S62 Emergency stop reset button K63 Relay for indicatio...

Page 10: ...If the drive fails to acknowledge the receivable of the emergency stop command in 2 seconds the STO cuts off the drive control pulses preventing motor control and torque generation 4 The drive decele...

Page 11: ...afety circuit The fault reaction function shifts the drive immediately into the safe state by activating the Safe torque off STO function switching on the drive emergency stop command and keeping it o...

Page 12: ...the motor is stopped when an emergency stop command is received 20 05 Emergency stop source DI1 Selects the source of the emergency stop signal In this case the source is DI1 23 23 Emergency stop tim...

Page 13: ...rement button to change the flashing segment d Push the Select button to change what segment or decimal point of the display is flashing e Push and hold the Select button to confirm the time value 7 P...

Page 14: ...channels separate If you use only one channel or if the first and second channels are connected together for example in a chain the cross fault detection of the emergency stop safety relay trips and a...

Page 15: ...ttings on page 12 Ensure that the motor can run and be stopped freely during the test Start the drive and ensure that the motor is running If possible use a motor speed close to the maximum speed of t...

Page 16: ...1 to 3 seconds 3 Reset the drive if necessary 4 Make sure that the drive has received the start signal depends on the configuration see the firmware manual 5 You can now restart the drive Note You ha...

Page 17: ...Check the supply voltage E 17 Temperature error Check the ambient temperature E 20 E 26 Input Output I O error 1 Power cycle the safety relay 2 If the error code remains contact your ABB Jokab Safety...

Page 18: ...closing both CH s at the same time fast flash green blue green Two channels error CH1 has been unaccepted and then accepted again while CH2 remained accepted Check installation Restore by opening and...

Page 19: ...page 15 The person responsible for the design of the complete safety function should also note the Requirements from IEC61800 5 2 2016 EN61800 5 2 2017 for the drives STO circuit 6 2 2 1 4 Diagnostic...

Page 20: ...3 e 5 4 E 8 90 3 1 80 20 20 1 1 PFH values are according to EN ISO 13849 2 DC depends on the used STO mode and directly reflects to needed test interval 3 See the recommendation of use CNB M 11 050 p...

Page 21: ...on you must document all acceptance tests Acceptance test reports You must store the signed acceptance test reports in the logbook of the machine The report must include as required by the referred st...

Page 22: ...assessment and risk reduction ISO 13849 1 2015 Safety of machinery Safety related parts of control systems Part 1 General principles for design EN ISO 13849 2 2012 Safety of machinery Safety related...

Page 23: ...tion A listing of ABB sales support and service contacts can be found by navigating to www abb com searchchannels Product training For information on ABB product training navigate to new abb com servi...

Page 24: ...y ABB Automation Products Wallstadter Stra e 59 68526 Ladenburg Germany Tel 49 0 6203 71 0 Fax 49 0 6203 71 76 09 www abb com dc drives 508R0201A0090000 508R0201A0090000 Ident No 3ADW000508R0201 Rev B...

Reviews: