
22 Introduction to the manual
describes the electrical installation process of the inverter.
contains a list for checking the mechanical and electrical installation
of the inverter.
describes the start-up procedure of the inverter.
describes the fault tracing possibilities of the inverter.
contains preventive maintenance instructions of the inverter.
contains the technical data for the inverter.
contains example dimension drawings of the inverter.
Related documents
See the inside of the front cover.
Categorization by frame size and option code
Some instructions, technical data, dimensions and weights which concern only certain
inverter frame sizes are marked with the symbol of the frame size, such as R8i. The frame
size is not marked on the inverter designation label. To identify the frame size of your unit,
see the rating tables in chapter
.
The instructions and technical data which concern only certain optional selections are
marked with option codes, eg, +Q951. The options included in the inverter can be
identified from the option codes visible on the type designation label. The option selections
are listed in section
on page
.
Quick installation, commissioning and operation
flowchart
Task
See
Plan the installation.
Check the ambient conditions, ratings, required cooling
air flow, input and output power connection, compatibility
with the solar generator and other technical data.
Select the cables.
Technical data
Planning the electrical installation
Option manual (if optional equipment is included)
Unpack and check the units.
Check that all necessary optional modules and
equipment are present and correct.
Only intact units may be started up.
page
)
.
If the converter has been non-operational for more
than one year, the converter DC link capacitors
need to be reformed. See
Capacitor reforming
instructions
(3BFE64059629 [English]).
Check the installation site.
Checking the installation site (
page
)
.
Route the cables.
(page
)
Summary of Contents for PVS800-57-0100kW-A
Page 1: ...ABB solar inverters Hardware manual PVS800 57 central inverters 100 to 1000 kW ...
Page 4: ......
Page 22: ...20 Safety instructions ...
Page 64: ...62 Operation principle and hardware description ...
Page 74: ...72 Mechanical installation ...
Page 90: ...88 Electrical installation PE PE PE ...
Page 124: ...122 Maintenance ...
Page 152: ...150 Dimension drawings Frame R7i 3AUA0000083128 ...
Page 153: ...Dimension drawings 151 AC output 3AUA0000083128 ...
Page 154: ...152 Dimension drawings 3AUA0000083128 One DC input Four DC inputs ...
Page 156: ...154 Dimension drawings R8i 8 DC inputs option 8H382 3AXD50000016935 ...
Page 157: ...Dimension drawings 155 R8i AC output terminals 3AXD50000016935 ...
Page 165: ...Dimension drawings 163 2 R8i AC output terminals 3AXD50000015007 ...
Page 173: ...Dimension drawings 171 3 R8i AC input terminals 3AXD50000015006 ...
Page 178: ...176 Dimension drawings ...
Page 180: ...Contact us www abb com solar 3AUA0000053689 Rev H EN EFFECTIVE 2014 07 09 ...