59
FEM630 |
ELECTROMAGNETIC FLOWMETER | OI/FEM630-EN REV. A
. . .7 Commissioning
Measuring range table
The upper range value can be set between 0.02 × Q
max
DN and 2 × Q
max
DN.
Nominal diameter
DN
in
Min . flow range end value
0.02 × Q
max
DN ≈ .656 ft/s (0.2 m/s)
Q
max
DN
0 to ≈ 32.8 ft/s (10 m/s)
Max . flow range end value
2 × Q
max
DN ≈ 65.6 ft/s (20 m/s)
3
¹⁄₁₀
0.08 l/min (0.02 US gal/min)
4 l/min (1.06 US gal/min)
8 l/min (2.11 US gal/min)
4
⁵⁄₃₂
0.16 l/min (0.04 US gal/min)
8 l/min (2.11 US gal/min)
16 l/min (4.23 US gal/min)
6
¼
0.4 l/min (0.11 US gal/min)
20 l/min (5.28 US gal/min)
40 l/min (10.57 US gal/min)
10
³⁄₈
0.9 l/min (0.24 US gal/min)
45 l/min (11.9 US gal/min)
90 l/min (23.78 US gal/min)
15
½
2 l/min (0.53 US gal/min)
100 l/min (26.4 US gal/min)
200 l/min (52.8 US gal/min)
25
1
4 l/min (1.06 US gal/min)
200 l/min (52.8 US gal/min)
400 l/min (106 US gal/min)
40
1½
12 l/min (3.17 US gal/min)
600 l/min (159 US gal/min)
1200 l/min (317 US gal/min)
50
2
1.2 m3/h (5.28 US gal/min)
60 m3/h (264 US gal/min)
120 m3/h (528 US gal/min)
80
3
3.6 m3/h (15.9 US gal/min)
180 m3/h (793 US gal/min)
360 m3/h (1585 US gal/min)
100
4
4.8 m3/h (21.1 US gal/min)
240 m3/h (1057 US gal/min)
480 m3/h (2113 US gal/min)