![ABB PRO-33.0-TL Series Service Manual Download Page 77](http://html.mh-extra.com/html/abb/pro-33-0-tl-series/pro-33-0-tl-series_service-manual_3045376077.webp)
Parameters 77
No.
Name/Value/Range
Description
Default
FbEq (16b/32b)
173 Inverter diagnostics
173.01
Uptime
Shows inverter uptime counter.
-
0 … 4294967295 h
- / 1 = 1 h
173.02
Operation time
Shows inverter operation time.
-
0 … 4294967295 h
1 = 1 h
173.03
Internal fan run time
Shows run time of internal fan.
0 h
0 … 4294967295 h
- / 1 = 1 h
173.04
External fan 1 run time
Shows run time of external fan 1.
0 h
0 … 4294967295 h
- / 1 = 1 h
173.05
External fan 2 run time
Shows run time of external fan 2.
0 h
0 … 4294967295 h
- / 1 = 1 h
173.06
Internal fan speed
Shows RPM of the internal fan.
0 rpm
0 … 10 000 rpm
1 = 1 rpm
173.07
External fan 1 speed
Shows RPM of external fan 1 located on the right
side of the inverter.
0 rpm
0 … 10 000 rpm
1 = 1 rpm
173.08
External fan 2 speed
Shows RPM of external fan 2 located on the left
side of the inverter.
0 rpm
0 … 10 000 rpm
1 = 1 rpm
173.18
Power-up tests
Shows number of times the inverter was powered
up.
-
0 … 4294967295
- / 1 = 1
173.19
Connection tests
Shows number of grid connection tests.
0
0 … 4294967295
- / 1 = 1
173.20
Grid connections
Shows amount of grid connections.
0
0 … 4294967295
- / 1 = 1
173.21
Ground impedance Zn
Shows measured impedance from negative pole
to ground.
0 MOhm
-1000 … 1000 MOhm
- /
1000 = 1 MOhm
173.22
Ground impedance Zp
Shows the measured impedance from positive
pole to ground.
0 MOhm
-1000 … 1000 MOhm
- /
1000 = 1 MOhm
173.23
Control board temperature Control board temperature.
-
0 … 127 °C
1 = 1 °C
173.24
Inverter temperature A
Inverter phase A IGBT module.
-
-80 … 150 °C
1 = 1 °C
173.25
Inverter temperature B
Inverter phase B IGBT module.
-
-80 … 150 °C
1 = 1 °C
173.26
Inverter temperature C
Inverter phase C IGBT module.
-
-80 … 150 °C
1 = 1 °C
Summary of Contents for PRO-33.0-TL Series
Page 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Page 4: ......
Page 8: ...8 ...
Page 12: ...12 Service menu ...
Page 36: ...36 Program features ...
Page 100: ...100 Parameters ...
Page 112: ...112 Tools ...
Page 121: ......
Page 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...