48 Parameters
114.45
AI2 unit selection
(
is FIO-11.
)
Selects the unit for readings and settings related
to analog input AI2.
Note
: This setting must match the corresponding
hardware setting on the I/O extension module
(see the manual of the I/O extension module).
The hardware setting is shown by parameter
.
mA
V
Volts
2
mA
Milliamperes
10
114.48
AI2 min
(
is FIO-11.
)
Defines the minimum value for analog input AI2.
0.000 mA or V
-22.000 .. 22.000 mA or V
Minimum value of AI2.
1000 = 1 mA or
V
114.49
AI2 max
(
is FIO-11
.)
Defines the maximum value for analog input AI2
10.000 mA or V
-22.000 … 22.000 mA or V Maximum value of AI2.
1000 = 1 mA or
V
114.50
AI2 scaled at AI2 min
(
is FIO-11.
)
Defines the real value that corresponds to the
minimum analog input AI2 value defined by
parameter
.
0.000
-32768.000 … 32767.000 Real value corresponding to minimum AI2 value. 1 = 1
114.51
AI2 scaled at AI2 max
(
is FIO-11
.)
Defines the real value that corresponds to the
maximum analog input AI2 value defined by
parameter
. See the drawing at
.
100.000
-32768.000 … 32767.000 Real value corresponding to maximum AI2 value. 1 = 1
114.56
AI3 actual value
(
is FIO-11
.)
Displays the value of analog input AI3 in mA or V
(depending on whether the input is set to current
or voltage). This parameter is read-only.
-
-22.000 … 22.000 mA or V Value of analog input AI3.
1000 = 1 mA or
V
114.57
AI3 scaled value
(
is FIO-11
.)
Displays the value of analog input AI3 after
scaling. See parameter
. This parameter is read-only.
-
-32768.000 … 32767.000 Scaled value of analog input AI3.
1 = 1
No.
Name/Value/Range
Description
Default
FbEq (16b/32b)
Summary of Contents for PRO-33.0-TL Series
Page 1: ...ABB solar inverters Service menu guide PRO 33 0 TL string inverters ...
Page 4: ......
Page 8: ...8 ...
Page 12: ...12 Service menu ...
Page 36: ...36 Program features ...
Page 100: ...100 Parameters ...
Page 112: ...112 Tools ...
Page 121: ......
Page 122: ...www abb com solarinverters Contact us 3AXD50000015823 Rev C EN 2017 06 29 ...