Charge air pressure too low
Engine performance and engine speed unchanged, suction condition normal
Possible causes
Remedy
Engine
Air receiver not sealed
Repair
Gas piping between engine and turbine
not sealed
Injection mistimed
Set correctly
Valve control misadjusted
Low-pressure or
high-pressure
stage
Manometer display not correct
Replace manometer
Supply pipe to manometer not sealed Repair leak
Filter silencer contaminated, therefore
pressure drop too high
Clean
Compressor/turbine contaminated
Compressor/turbine damaged
Contact ABB Turbocharging Service Sta-
tion
Exhaust gas back pressure too high
Clean or repair boiler or exhaust gas si-
lencer
Table 25: Malfunctions during operation – Charge air pressure too low
Charge air pressure too high
Engine performance and engine speed unchanged, suction condition normal
Possible causes
Remedy
Engine
Malfunction in the injection system
Repair or contact manufacturer
Injection mistimed
Set correctly
Engine performance higher than ex-
pected
Check engine performance
Low-pressure or
high-pressure
stage
Manometer display not correct
Replace manometer
Table 26: Malfunctions during operation – Charge air pressure too high
Summary of Contents for Power2 850-M16
Page 28: ......
Page 32: ......
Page 42: ......
Page 44: ......
Page 70: ......
Page 78: ......
Page 80: ......
Page 82: ......
Page 86: ......
Page 88: ......
Page 90: ......
Page 92: ......
Page 94: ......
Page 96: ......
Page 100: ......
Page 130: ......
Page 134: ......
Page 138: ......
Page 140: ......
Page 142: ......
Page 178: ......