Operation Manual / Power2 850-M / 4.1 Low-pressure stage
2
Removal and installation
Page 5 / 49
© Copyright 2015 ABB. All rights reserved.
HZTL4062_EN
Revision -
December 2015
2
Removal and installation
2.1
Transport / weight
Swivel lifting eyes to be used
Two swivel lifting eyes (S) are required for the safe lifting of loads. These are not included in
the ABB Turbo Systems scope of delivery.
Swivel lifting eye (S)
Power2
Thread
Length
L
Minimum load
limit
850 LP
M24
30 mm
1800 kg
Table 2: Swivel lifting eyes to be used
Lifting gear with a sufficient load limit must be used for removing and installing the low-
pressure stage. The following weight specification is the heaviest variant possible. This
standard value may deviate from the data on the rating plate depending on the specification.
Complete low-pressure stage
Suspension
Weight [kg]
1800
Table 3: Transporting the low-pressure stage