Operation Manual / Power2 850-M / 4.2 High-pressure stage
4 Disassembly and assembly / 4.6 Removing the cartridge group
© Copyright 2017 ABB. All rights reserved.
HZTL4063_EN
Revision A
August 2017
4.6
Removing the cartridge group
Fig. 9: Moving out cartridge group 1
1. Remove the O-ring (42010).
2. Undo and remove screws (42099).
3. Fit bracket (90030) and fit swivel lifting eye (90657) to cartridge group with screws
(90900).
4. Move in three plates (90031).
5. To secure, fit plate (90032) with screw (90656) and nut (90415).
6. Secure lifting gear to swivel lifting eye (90657).
Fig. 10: Moving out cartridge group 2
7. Evenly press off cartridge group by screwing three press-off screws (90901) into the des-
ignated holes.
8. Carefully move out cartridge group.