Description
I/O signal name
Digital output for activating vacuum. For example, for gripping
a product. The output signal is set when an item shall be at-
tached to the tool.
Note
The signal is controlled from the RAPID program. In simulation,
the RAPID
triggdata SimAttachX
controls when the signal
is set. On a real robot, the RAPID
triggdata VacuumActX
controls when the signal is set.
doVacuumX
Digital output for activating air blow. For example, for releasing
a product gripped by the robot. The output signal is set when
an item shall be detached from the tool.
Note
The Release signal is controlled from the RAPID program. In
simulation, the RAPID
triggdata SimDetachX
controls when
the signal is set. On a real robot, the RAPID
triggdatas
VacuumRevX
and
VacuumOffX
controls when the signal is
set/pulsed.
doBlowX
Digital I/O group containing
doVacuumX
and
doBlowX
.
goVacBlowX
Modify I/O signals in work area
Use this procedure to create a ghost picking flow:
1 Right-click on
Conveyor WA 1
in the tree view
Cell
and select
Setting
.
xx1800001733
Continues on next page
178
Application manual - PickMaster® Twin - PowerPac
3HAC064218-001 Revision: B
© Copyright 2021 ABB. All rights reserved.
4 Working with PickMaster PowerPac
4.3.1 Switching to real Runtime
Continued
Summary of Contents for PickMaster Twin - PowerPac
Page 1: ...ROBOTICS Application manual PickMaster Twin PowerPac ...
Page 8: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 420: ...This page is intentionally left blank ...
Page 444: ...This page is intentionally left blank ...
Page 446: ...This page is intentionally left blank ...
Page 448: ...This page is intentionally left blank ...
Page 452: ......
Page 453: ......