Note/Illustration
Action
xx2300000753
Reconnect the free ends of the 24V ad-
apter harness:
•
Wire K7-W201 to the 24V (V+)
connection on the Connected
Services gateway.
•
Wire K7-W202 to the 0V (V-) con-
nection on the Connected Ser-
vices gateway.
4
Reconnect any connectors disconnected
at removal.
5
Reconnecting the antenna
Note/Illustration
Action
Note
The operating conditions must be such that
there is a minimum separation distance of
20 cm between the dedicated antenna and
nearby persons.
Place the magnet part of the antenna on
the outside of the cabinet.
1
Note
The Connected Services antenna is installed
by the customer, and the cable routing can
therefore differ.
Follow the cable routing recorded during
the disassembly when you reconnect the
antenna cable.
2
Continues on next page
Product manual - OmniCore V250XT Type B
223
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
5 Repair
5.2.5 Replacing the 4G Connected Services gateway
Continued