19
1> 1.000
2> 1.000
Q >
Flow Probe Ins
Flow Probe Prof
Flow Probe Quit
Main Menu
Sub-menus
Remarks
6
Flow Probe
6 >
Flow %
Flow Cutoff
Flow Quit
7 >
8 >
Q >
Anlg
5
5>
Anlg Fsd
Anlg Zero
Anlg Dir
1 > 20
2 > 4
3 >
3
1> 1
2> 0
Q>
Anlg Dir Fwd
Anlg Dir Rev
Anlg Dir Quit
Anlg No 2
Anlg mA
4 >
5 >
Requires Level 2 access>
#
#
Set additional parameters for insertion probes.
Insertion factor for probes (default = 1.000).
Flow profile correction factor (default = 1.000).
Enter Q (CR) to return to Flow Menu or (CR) to
cycle around this menu.
Displays current flow as percentage of range.
Flow velocity in mm/s below which all outputs are set to zero. (default = 5)
Enter Q (CR) to return to Main Menu or (CR) to cycle around this menu.
Enter output current in mA for 100% flow (0
≤
FSD
≤
21).
Enter output current in mA for 0% flow (0
≤
ZERO
≤
21).
Select direction(s) of operation for analogue output.
Analogue output responds to forward flow.
Analogue output responds to reverse flow.
Enter Q (CR) to return to Anlg Menu or (CR) to
cycle around this menu.
Full scale flow range for second analogue range, as percentage of main flow
range (default = 100%)
Displays present output current in mA.
Enter Q (CR) to return to Main Menu or (CR) to cycle around this menu.
1>
2>
3>
4>
5>
6>
Q>
Pls Fact
Pls Cutoff
Pls Max
Pls Hz
Pls Idle
Pls Size
Pls Quit
6
Enter required output pulses per flow volume unit.
Flow rate (%) below which pulse output and
totaliser cease to operate.
Maximum output frequency in Hz.
Enter Q (CR) to return to Main Menu or (CR) to
cycle around this menu.
Anlg Quit Q>
Display of present value of output frequency in Hz.
Pulse output level in idle (off) state.
Enter output pulse width in msecs. (Value will be
rounded up to nearest 10msec.) - Set to '0' for
square wave output.
* Select both parameters for bidirectional operation
(e.g. when dual current output is fitted).
If both are zero, then |out is also 0%.
#
Pls
6>
Requires Level 2 access>
Requires Level 2 access>
…B1.2
Description of Parameters
…APPENDIX B