background image

 

 

2TLC172133M0201, rev. A 

www.jokabsafety.com 

2011-09-22  

4  Installation and maintenance  

Installation precautions 

The unit must first attach to the M12 male connector and then the M12 female connector with the loops to the door 
edges or safety mats. 

 

Warning!

 All the safety functions must be tested before starting up the system. 

Maintenance 

  Warning!  

The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the 
safety functions are working properly (EN 62061:2005). 

In case of breakdown or damage to the product, contact the nearest ABB/Jokab Safety Service Office or reseller. 
Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, 
impairing the safety of the device which in turn could lead to serious injury to personnel. 

Testing of the safety functions 

Make sure the safety unit is working properly by following these steps: 

  Interrupt the dynamic safety circuit before this unit. The LED should flash between green and red.  

  Interrupt protection. The LED should light red.  

  The LED should light green when protection is OK and if the safety circuit(s) before this unit is not 

interrupted. 

Troubleshooting 

LED indication 

Expected causes of faults 

Checking and measures to take 

Lights red 

Sensor open 

Check status of the sensor 

Bad connection between loops 

Check terminals at the door sensitive 
edges/and fasten them carefully 

24 VDC input to pin-2 (no dynamic signal) 

Check if there is 24 VDC to input (pin-2). If 
Yes, check cable or unit before and fix it. 

No lights 

Loss of power supply 

Check 24 VDC / 0 VDC power supply 

Lights green (but no dynamic output 
detected) 

Defected dynamic signal input to unit 
(asymmetric pulses) 

Check the dynamic input or the unit before 

Weak lights or red and green lights at the 
same time 

The unit is defect 

The unit needs to be replaced. Contact 
ABB/Jokab Safety. 

NB: Tina 1A can be used instead of this unit to check if the safety circuit is OK (

only

 for test). 

 Warning! 

Replace defected unit with a new one and never bypass the safety circuit using Tina 1A or any other 

solution.

 

Summary of Contents for JOKAB SAFETY Tina 6A

Page 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www jokabsafety com Original instructions Tina 6A Adaptor unit ...

Page 2: ...FETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attentio...

Page 3: ...iew 5 General description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 8 Installation precautions 8 Maintenance 8 Testing of the safety functions 8 Troubleshooting 8 5 Operation 9 LED indication 9 Information output signal attributes 9 6 Technical data 10 Dimensions 11 7 EC Declaration of conformity 12 ...

Page 4: ... this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipment An...

Page 5: ...s also equipped with a LED for visual status information of the safety sensor and the dynamic safety circuit The Tina 6A adaptor unit is intended for use in safety circuits in accordance with EN 60204 1 Safety regulations Warning Carefully read through this entire manual before using the device The devices shall be installed by a trained electrician following the Safety regulations standards and t...

Page 6: ... be used for the safety purpose s The safety loops shall not be used for purposes other than intended All loading or tampering with loops can lead to serious risk of life M12 connector male 1 Brown 24 VDC 2 White Dynamic signal input 3 Blue 0 VDC 4 Black Dynamic signal output 5 Grey Information M12 connector female 1 Brown Loop A1 2 White Loop A2 3 Blue Loop B1 4 Black Loop B2 5 Grey Not used M12 ...

Page 7: ...rev A 7 www jokabsafety com 2011 09 22 Connection examples Caution All cable colours according to ABB Jokab Safety standard cables More connection examples can be found at www jokabsafety com or in the Safety Handbook ...

Page 8: ...c safety circuit before this unit The LED should flash between green and red Interrupt protection The LED should light red The LED should light green when protection is OK and if the safety circuit s before this unit is not interrupted Troubleshooting LED indication Expected causes of faults Checking and measures to take Lights red Sensor open Check status of the sensor Bad connection between loop...

Page 9: ...is applied high H 0 VDC The pin is connected to 0 VDC low L The information output signal depends on the input signal according to the table below Note that if the safety is interrupted the information output signal is always low L Input signal pin 2 Dynamic signal No dynamic signal 24 VDC 0 VDC Info output signal pin 5 High High Low High The delay for switching the information signal output from ...

Page 10: ... OK and 24 VDC supply voltage Dynamic input between 9 and 13 volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class IP67 Ambient temperature Storage 30 70 C Operation 10 55 C Humidity range 35 to 85 with no icing or condensation Housing material PVC Connectors M12 5 pole male M12 5 pole female Size 62 x 33 x 15 L x W x H Weight 30 g Colour Black Safety...

Page 11: ...2TLC172133M0201 rev A 11 www jokabsafety com 2011 09 22 Dimensions Tina 6A NB All measurements in millimetres ...

Page 12: ...o compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 207 10 372092 001 000 000 999 999 Adapter unit Tina 1 8 Tina 10 12 44 207 10 372092 001 000 000 999 999 Muting unit FMC Tina 44 207 10 372092 001 000 000 999 999 Non contact safety sensor including locki...

Reviews: