background image

 

 

2TLC172133M0201, rev. A 

12 

www.jokabsafety.com 

2011-09-22  

7  EC Declaration of conformity 

 

 

 

ABB AB / JOKAB SAFETY

 Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden 

www.jokabsafety.com 

www.abb.com
www.jokabsafety.com

Original

EC Declaration of conformity

(according to 2006/42/EC, Annex2A)

We

ABB AB
JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden

declare that the safety components of ABB AB make with type designations and safety
functions as listed below, is in conformity with the Directives
2006/42/EC
2006/95/EC
2004/108/EC

Person authorised to compile
the technical file

Lars-Magnus Felth
ABB AB

JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden

Product

Certificate

Serialnumber

Non-contact safety sensor
Eden (Adam , Eva) E/C/EC

44 207 10 372092-001

[000 – 000 ... 999-999]

Adapter unit
Tina 1-8, Tina 10-12

44 207 10 372092-001

[000 – 000 ... 999-999]

Muting unit
FMC-Tina

44 207 10 372092-001

[000 – 000 ... 999-999]

Non-contact safety sensor
including locking function
Magne 2A, 2B, 2AX, 2BX

44 207 10 372092-001

[000 – 000 ... 999-999]

Notified body

TÜV NORD CERT GmbH
Langemarckstrasse 20
45141 Essen
Germany

Notified body No. 0044

Used harmonized standards

EN ISO 12100-1,-2, EN 954-1, EN ISO 13849-1, EN 62061, EN 60204-1,
IEC 60664-1, EN 61000-6-2, EN 61000-6-4, EN 60947-5-1, EN 1088

Mats Linger
MD
Kungsbacka 2011-03-02

Summary of Contents for JOKAB SAFETY Tina 6A

Page 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www jokabsafety com Original instructions Tina 6A Adaptor unit ...

Page 2: ...FETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attentio...

Page 3: ...iew 5 General description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 8 Installation precautions 8 Maintenance 8 Testing of the safety functions 8 Troubleshooting 8 5 Operation 9 LED indication 9 Information output signal attributes 9 6 Technical data 10 Dimensions 11 7 EC Declaration of conformity 12 ...

Page 4: ... this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipment An...

Page 5: ...s also equipped with a LED for visual status information of the safety sensor and the dynamic safety circuit The Tina 6A adaptor unit is intended for use in safety circuits in accordance with EN 60204 1 Safety regulations Warning Carefully read through this entire manual before using the device The devices shall be installed by a trained electrician following the Safety regulations standards and t...

Page 6: ... be used for the safety purpose s The safety loops shall not be used for purposes other than intended All loading or tampering with loops can lead to serious risk of life M12 connector male 1 Brown 24 VDC 2 White Dynamic signal input 3 Blue 0 VDC 4 Black Dynamic signal output 5 Grey Information M12 connector female 1 Brown Loop A1 2 White Loop A2 3 Blue Loop B1 4 Black Loop B2 5 Grey Not used M12 ...

Page 7: ...rev A 7 www jokabsafety com 2011 09 22 Connection examples Caution All cable colours according to ABB Jokab Safety standard cables More connection examples can be found at www jokabsafety com or in the Safety Handbook ...

Page 8: ...c safety circuit before this unit The LED should flash between green and red Interrupt protection The LED should light red The LED should light green when protection is OK and if the safety circuit s before this unit is not interrupted Troubleshooting LED indication Expected causes of faults Checking and measures to take Lights red Sensor open Check status of the sensor Bad connection between loop...

Page 9: ...is applied high H 0 VDC The pin is connected to 0 VDC low L The information output signal depends on the input signal according to the table below Note that if the safety is interrupted the information output signal is always low L Input signal pin 2 Dynamic signal No dynamic signal 24 VDC 0 VDC Info output signal pin 5 High High Low High The delay for switching the information signal output from ...

Page 10: ... OK and 24 VDC supply voltage Dynamic input between 9 and 13 volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class IP67 Ambient temperature Storage 30 70 C Operation 10 55 C Humidity range 35 to 85 with no icing or condensation Housing material PVC Connectors M12 5 pole male M12 5 pole female Size 62 x 33 x 15 L x W x H Weight 30 g Colour Black Safety...

Page 11: ...2TLC172133M0201 rev A 11 www jokabsafety com 2011 09 22 Dimensions Tina 6A NB All measurements in millimetres ...

Page 12: ...o compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 207 10 372092 001 000 000 999 999 Adapter unit Tina 1 8 Tina 10 12 44 207 10 372092 001 000 000 999 999 Muting unit FMC Tina 44 207 10 372092 001 000 000 999 999 Non contact safety sensor including locki...

Reviews: