10/100Mbps Dual Speeds 

Fast Ethernet 

PC Card Ethernet 

A

dapter

 

 

 

Quick Installation Guide

 

Summary of Contents for FE1000

Page 1: ...10 100Mbps Dual Speeds Fast Ethernet PC Card Ethernet Adapter Quick Installation Guide ...

Page 2: ...nfiguration Please refer to Software Installation on how to install network drivers using menu driven installation utility Inserting the Dual Speeds Fast Ethernet PC Card 1 Hold the PC Card with wide connector toward the slot and the brand label facing upward 2 Insert the PC Card and push it firmly into the bottom Please see the figure on the next page for reference Removing the Dual Speed Fast Et...

Page 3: ...licks in place at both sides Attention should be paid when removing the 15 pins connector Please press the both sides of the connectors before dragging out of the PC Card Connecting to the Network Connect unshielded twisted pair UTP cable to the RJ 45 connector of media coupler before loading any network driver symbol 108 f Monotype Sorts s 6O For operation in the100Mbps 100Base TX Ethernet networ...

Page 4: ...00Mbps hub or switch symbol 108 f Monotype Sorts s 6O For operation in the 10Mbps 10Base T Ethernet network Category 3 4 or 5 unshielded twisted pair UTP cable could be used to connect between the media coupler and a 10Mbps hub or switch LED Indicators 3 ...

Page 5: ...ode drivers such as ODI or NDIS 2 x or Packet Drivers into the target disk Novell Netware There are two methods to install the Netware client ODI driver the menu installation and Netware 3 12 or 4 x Client installation Menu Installation 1 Run INSTALL EXE from the root directory of driver diskette 2 Select Netware 3 x and 4 x Workstation item from menu 4 ...

Page 6: ... starts copying related files from diskette to the destination directory and modifies AUTOEXEC BAT and NET CFG under usersymbol 146 f Parisian BT s 10 s agreement 6 Now the installation is completed Please reboot the computer to make your Netware connection If you wanted to install the ODI driver by manual you may follow the instructions list below 1 Copy the files LE100ODI COM and NET CFG from th...

Page 7: ...ver 3 Follow Novell s instructions on using ODI programs You can substitute the LE100ODI COM whenever a reference is made to the Hardware Specific Module 4 A typical ODI workstation startup batch file includes LANEN IRQ dd IOP xxx Card Enabler LSL Link Support Layer Module provided by Novell LE100ODI Hardware Specific Module IPXODI IPX Protocol Stack Module provided by Novell NETx Shell Support Mo...

Page 8: ...ram then modifies your AUTOEXEC BAT and CONFIG SYS files accordingly and creates backup copies 4 The following message appears Install support for MS Windows Y N 5 Answer accordingly and provide a path if necessary 6 The program displays the following Configure your workstation for backup by a NetWare server running software such as BACKUP Y N 7 Answer accordingly and provide a path if necessary 8...

Page 9: ...y files for NetWare Client Continue the installation procedure to completion Upon completion a new NET CFG file will be created in your DOS directory Typically this file contains the following lines Link Driver LE100ODI FRAME Ethernet_802 3 FRAME Ethernet_802 2 15 Copy the file LANEN EXE from the directory ENABLER in the driver diskette to Netware Client directory 16 Edit the STARTNET BAT by a tex...

Page 10: ...nge to connected device LOGIN xxx Login to file server as user xxx 17 Run STARTNET to access the Novell network MS LAN Manager 1 View the README TXT on the installation diskette in the NDIS2 directory Before installing the drivers please ensure that the Microsoft LAN Manager has been installed in the target path The installation program will check and modify the PROTOCOL INI file for LAN Manager 2...

Page 11: ...make a change and press Enter to select a fit value When the configuration are set completely press Enter on the OK field to exit the screen and go back to step 4 6 Installation program starts to copy related files from driver diskette to the destination directory and modifies CONFIG SYS and PROTOCOL INI under usersymbol 146 f Parisian BT s 10 s agreement 7 Please reboot the computer to load drive...

Page 12: ... LAN Manager PROTMAN DRIVERNAME PROTMAN DYNAMIC YES PRIORITY NETBEUI NETBEUI_XIF Drivername netbeui SESSIONS 6 NCBS 12 BINDINGS LE100NDS_NIF LANABASE 0 LE100NDS_NIF protocol ini session for LAN driver IOADDRESS 0x320 INTERRUPT 11 11 ...

Page 13: ...ter to select a fit value When the configuration are set completely press Enter on the OK field to exit the screen and go back to step 3 5 Installation program starts to copy related files from diskette to the destination directory and modifies AUTOEXEC BAT under usersymbol 146 f Parisian BT s 10 s agreement 6 Please reboot the computer to load the driver ODI Driver for Workgroups 1 Run Windows fo...

Page 14: ...r 6 In Network Drivers dialog box press Add Adapter button to enter Add Network Adapter dialog box Select Unlisted or Updated Network Adapter and press OK 7 Windows will prompt an Install Driver dialog box In this time put the driver diskette into floppy drive and press OK 8 Select the Netware ODI Driver string and press OK 9 Follow Windows instructions to complete the installation and exit Window...

Page 15: ... go back to step 11 14 Select Novell Netware Server as the network server you will attach to and press Enter key 15 Installation program starts to copy related files to the destination directory and modifies AUTOEXEC BAT and NET CFG under usersymbol 146 f Parisian BT s 10 s agreement 16 Please reboot the computer to have the driver take effect Windows NT 4 0 Assumed that the Network Services alrea...

Page 16: ...adjust the driver s settings The resources assignment to the adapter must be unique in the system 12 Press OK when all settings are completed 13 Press Close to complete network setting Windows 95 Installation 1 Assumed that the drivers of PC Card slot are well installed The System Icon in the Control Panel can report on its functionality Apart from above mentioned any questions on this layer need ...

Page 17: ...ert driver diskette The driver will be installed and you may be asked for the original Windows 95 CD disks 4 For the first time installation please click Network icon in Control Panel to add Protocols Client and Service if you needed 5 Reboot the machine and the card will be fully functional Artisoft Lantastic 6 0 Installation 1 Install LANTASTIC 6 0 first 16 ...

Page 18: ... to select a fit value When the configuration is set completely press Enter on the OK field to exit the screen and go back the step 4 6 Installation program starts to copy the related files from diskette to the destination directory and modifies CONFIG SYS PROTOCOL INI and STARTNET BAT under usersymbol 146 f Parisian BT s 10 s agreement 7 Please reboot the computer to have the driver take effect I...

Page 19: ...ice of OS 2 Warp 1 In the OS 2 Desktop group double click on the OS 2 System icon 2 Double click on the System Setup icon 3 Double click on the Selective Install icon 4 Select the PCMCIA Support button 5 Select PCMCIA system For example select IBM ThinkPad 750 6 Click OK 7 Click Install 8 Select the source drive and directory For Example D OS2IMAGE 9 Click Install 10 Click OK B Install NDIS2 drive...

Page 20: ... the Configure button 5 Select the Other adapters option 6 Insert the driver diskette and type the driver path A OS2 NDIS2 Click on the OK button 7 Select PCMCIA Ethernet Adapter and then click on the Add button 8 Select IBM OS 2 NETBIOS and then click on the Add button 9 Click OK 10 Click Close 11 Click Exit 12 Shutdown and restart your system 19 ...