3 Maintenance
3.4.7. Replacement of SMB battery
3HAC028197-001 Revision: A
134
©
Co
py
rig
h
t 200
7-
200
8 ABB. All righ
ts reser
v
ed.
Refitting, battery
The procedure below details how to refit the SMB battery.
2.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
3.
esd
WARNING!
The unit is sensitive to ESD, before handling the
unit please observe the safety information in
section
WARNING - The unit is sensitive to ESD!
4. Remove the
SMB battery cover
by unscrewing its
attachment screws.
Shown in the figure
.
5. Pull out the battery and disconnect the
battery
cable
.
Shown in the figure
.
6. Remove the
SMB battery.
Battery includes protection circuits. Replace it
only with the specified spare part or with an ABB
approved equivalent.
Shown in the figure
.
Action
Note
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
2.
esd
WARNING!
The unit is sensitive to ESD, before handling
the unit please observe the safety information
in section
WARNING - The unit is sensitive to
3. Reconnect the
battery cable
to the
SMB battery
pack
and fit it to the frame.
Shown in the figure
4. Secure the
SMB battery cover
with its
attachment screws.
Shown in the figure
Continued
Continues on next page
Summary of Contents for IRB 6660 - 130/3.1
Page 1: ...Product manual Articulated robot IRB 6660 130 3 1 IRB 6660 205 1 9 M2004 ...
Page 2: ......
Page 332: ... 0 1 23 3 4 5 5 6 2 70 2 888 2 9 6 0 9 9 2 A 8B C D 9 8 B ...
Page 333: ... 2 3 4 5 5 6 2 70 2 888 2 9 6 0 9 9 1 EF 2 888 2 9 6 9 9 8 B ...
Page 336: ... 98 2 888 7 066 0 10I 4 5 5 06 6 2 70 2 888 2 9 6 0 9 9 G E 7 F E 7 F 9 8 B ...
Page 347: ......