Requirements, foundation
The table shows the requirements for the foundation where the weight of the
installed robot is included:
Note
Value
Requirement
Flat foundations give better repeatability of the
resolver calibration compared to original settings
on delivery from ABB.
0.5 mm
Maximum deviation
from levelness
The value for levelness aims at the circumstance
of the anchoring points in the robot base.
The limit for the maximum payload on the robot
is reduced if the robot is tilted from 0°.
5°
Maximum tilt
Contact ABB for further information about accept-
able loads.
30 Hz
Minimum resonance
frequency
Storage conditions, robot
The table shows the allowed storage conditions for the robot:
Value
Parameter
-25° C
Minimum ambient temperature
+55° C
Maximum ambient temperature
+70° C
Maximum ambient temperature (less than 24 hrs)
Max.100% at constant temperat-
ure (gaseous only)
Maximum ambient humidity
Operating conditions, robot
The table shows the allowed operating conditions for the robot:
Value
Parameter
+5° C
Minimum ambient temperature
+45° C
Maximum ambient temperature
Max.100% at constant temperat-
ure (gaseous only)
Maximum ambient humidity
Protection classes, robot
The table shows the protection class of the robot:
Protection class
Equipment
IP 67
Manipulator, protection type Standard
56
3HAC026048-001 Revision: E
© Copyright 2006-2013 ABB. All rights reserved.
2 Installation and commissioning
2.2.1 Pre-installation procedure
Continued
Summary of Contents for IRB 260
Page 1: ...ABB Robotics Product manual IRB 260 ...
Page 8: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 214: ...This page is intentionally left blank ...
Page 216: ...This page is intentionally left blank ...
Page 260: ...This page is intentionally left blank ...
Page 266: ......
Page 267: ......