Commissioning
Operating Instructions 2TMD041700D0041
│
32
Zone attribute description
[1] Instant zone
This type of zone will start detection when armed. Once the zone is triggered, an alarm is
issued immediately. Turn off the alarm by disarming.
[2] Delay zone
This type of zone will raise an alarm when the people fail to exit or enter the delay zone in time.
When the zone is armed, the detector starts the countdown for the exit delay and detects the
area after the specified time. If the detector is triggered, it starts the countdown for the enter
delay. The user must disarm the zone before the end of the countdown, or the alarm is issued
when the countdown has expired.
[3] Trans. delay zone
This type of zone is used to cooperate with the delay zone. When the zone is armed, the
detector starts the countdown for the exit delay and detects the area after the specified time. If
Trans. delay zone is triggered first, the alarm will be issued immediately. If the delay zone is
triggered first, it starts the countdown for the enter delay. The user must disarm the zone before
the end of the countdown, or the alarm is issued when the countdown has expired.
[4] 24-hour zone
This type of zone works for 24 hours a day. The detector starts to detect when it is powered on.
If the zone is triggered, the alarm will be issued immediately. (whether the zone is armed or
disarmed) The alarm cannot be closed by disarming the zone, the only way to close the alarm is
to disable the zone.
Fig. 27: Zone details
"Zone Details" can be clicked to set the location of the zone, groups of zones and whether or
not there is a link with a zone.
Click "OK" to save.