F O X C S T R E F E R E N C E
FOX61x
LEDE1
33
−
“Main - Inventory”,
−
“Main - Logbooks”, and
−
“Main - Software”
management functions description, please refer to
8.2.3
AP: / unit-x, Fault Management
For the a description of the general aspects of the
−
“Fault Management - Status”, and
−
“Fault Management - Configuration”
management functions, please refer to
The following table lists the fault causes of the current AP.
Table 8:
AP: / unit-x, Fault Management
ID
Fault Cause
Event Type
Traffic
Affecting
Default
Severity
Description
SWM
Software Mismatch
Equipment
Alarm
Minor
The running ESW does not match the
assigned ESW.
SSWNA
Scheduled Software
Not Available
Equipment
Alarm
Minor
The ESW that is scheduled for installa-
tion is not available on the unit. Make
sure that the ESW is downloaded to the
unit.
SWIN
Software Incompatible
With Network Element
Equipment
Alarm
Major
The running ESW is not compatible with
the version required by the NE type or
version.
PRC
PBUS Resource Con-
flict
Processing
Error Alarm
Major
The PBUS access circuit of another TDM
unit in the subrack is defective.
Remove or unassign the other TDM units
in the subrack one by one until the alarm
is cleared. Replace the defective unit.
EQM
Equipment Malfunction Equipment
Alarm
Critical
The LEDE1 controller detects any anom-
alies on the unit, e.g. a voltage is miss-
ing, a chip does not respond, etc.
HWIC
Hardware Incompatible
With Configuration
Equipment
Alarm
Major
The plugged HW is not compatible with
the unit configuration HW stored in the
database. You may need to change the
HW or re-create the configuration for the
unit.
SWIC
Software Incompatible
With Configuration
Equipment
Alarm
Major
The ESW running on the unit is not com-
patible with the unit configuration stored
in the database. You may need to
upgrade, or downgrade the ESW, or re-
create the configuration with the cur-
rently running ESW.
GSW
General Software
Alarm
Equipment
Alarm
Major
An ESW internal error has been detected
that might inhibit the ESW from running
correctly.
MFA
Maintenance Function
Active
Communica-
tion Alarm
Warning
A maintenance function has been acti-
vated by the operator.
UNAV
Unit Not Available
Equipment
Alarm
Critical
The unit that is configured is either not
plugged or not recognized due to a fail-
ure.
Summary of Contents for FOX61 Series