F O X C S T R E F E R E N C E
FOX61x
LEDE1
37
Risk of operating trouble!
Changing the P12 termination mode results in most cases in incompatible
layer rates or number of timeslots.
→
The channel with its CTP and the assigned connections are deleted
automatically and must be newly created.
→
Please refer to
"1KHW002467 FOX61x TDM Services"
, section 4.2.2.
8.3.3.2
AP: / unit-x / port-y, Configuration - Synchronization
Table 11:
AP: / unit-x / port-y, Configuration - Synchronization
Operation Name
Parameter Name Range
Description / Details
Synchronization
Method
None
Do not use a synchronization method
SSM-Sa4
Use the selected Sa bit in time slot 0 for the
transport of the synchronization status message
(SSM).
These parameter values are only available with
the termination modes “PCM30C” and
“PCM31C”.
SSM-Sa5
SSM-Sa6
SSM-Sa7
SSM-Sa8
SSI-Sa5
Use the Sa5 bit in time slot 0 for the transport of
the synchronization status indication (SSI).
The SSI method is ABB proprietary and is com-
patible with the FOX51x.
This parameter value is only available with the
termination modes “PCM30”, “PCM30C”,
“PCM31” and “PCM31C”.
QL Transmission
Source
ESI-1
Synchronization sources are all the PDH clock
sources as they are configured at the AP: /ne,
Configuration - PETS
ESI-2
<PDH Clock Source 1>
<PDH Clock Source 2>
<PDH Clock Source 3>
<PDH Clock Source 4>
Internal
Usage
NA
No synchronization method has been selected.
CanBeUsed
Transmit the QL value of the selected synchroni-
zation source
DoNotUse
Transmit the QL value 15, i.e. indicating that the
traffic signal cannot be used as a synchroniza-
tion source.