F O X C S T R E F E R E N C E
48
FOX61x
LEDE1
Table 24:
AP: / unit-x / port-y / chan-z, Status - CTP
Operation Name
Parameter Name Range
Description / Details
Trail Status
Working Trail,
Remote CTP
<MO Address>
Managed object address of the CTP (connec-
tion termination point) where the P12 or P0-nc
signal is connected to, e.g. /unit-21/port-1/chan-
1.
Working Trail, Sta-
tus
OK
No failure on the received signal.
SF
Signal Fail status on the received signal.
CAS AIS
CAS AIS status in the received signal, i.e. an all
‘1’ signal in time slot 16.
SD
Signal Degraded status on the received signal.
Not Available
The status of the received signal is not available,
e.g. when the CTPs role is a-end in a unidirec-
tional connection.
Protecting Trail,
Remote CTP
<MO Address>
Managed object address of the CTP (connec-
tion termination point) where the P12 or P0-nc
signal is connected to, e.g. /unit-21/port-2/chan-
1.
Protecting Trail,
Status
OK
No failure on the received signal.
SF
Signal Fail status on the received signal.
CAS AIS
CAS AIS status in the received signal, i.e. an all
‘1’ signal in time slot 16.
SD
Signal Degraded status on the received signal.
Not Available
The status of the received signal is not available,
e.g. when the CTPs role is a-end in a unidirec-
tional connection.
Active Trail
Working
The trail from the a-end working remote CTP has
been selected.
Protecting
The trail from the a-end protecting remote CTP
has been selected.
Not Available
There is no active trail.
External Request
Request
Release
Automatic trail selection.
Force Working
Force the selector to use the trail from the a-end
working remote CTP.
Force Protecting
Force the selector to use the trail from the a-end
protecting remote CTP.
Manual Working
Prefer the trail from the a-end working remote
CTP. Use this trail only if the fault status is not
worse than the fault status of the protecting trail.
Manual Protecting
Prefer the trail from the a-end protecting remote
CTP. Use this trail only if the fault status is not
worse than the fault status of the working trail.