F O X C S T R E F E R E N C E
FOX61x
LEDE1
43
8.3.5.2
AP: / unit-x / port-y, Status - QL
8.4
AP: / unit-x / port-y / chan-z
8.4.1
AP: / unit-x / port-y / chan-z, Main
8.4.1.1
AP: / unit-x / port-y / chan-z, Main - General
For a description of the
−
“Overview - Alarms”,
−
“Overview - Cross Connections”, and
−
“Overview - CTP”
management functions, please refer to
8.4.2
AP: / unit-x / port-y / chan-z, Main
8.4.2.1
AP: / unit-x / port-y / chan-z, Main - General
For a description of the
−
“Main - General”
Table 17:
AP: / unit-x / port-y, Status - QL
Operation Name
Parameter Name Range
Description / Details
Clock Quality
Received QL
Unknown
The synchronization method “None” has been
configured.
Do Not Use
Received SSM value = 15.
The received SSI value = 0 is interpreted as “Do
Not Use” and gets the QL = 15 assigned.
1 … 14
Display of the received SSM value < 15.
The received SSI value = 1 is interpreted as
“Can Be Used” and gets the QL = 13 assigned.
Transmitted QL
Unknown
The synchronization method “None” has been
configured.
Do Not Use
The “Do Not Use” quality level is transmitted as
SSM value = 15, or as SSI value = 0.
1 … 14
Display of the transmitted SSM value < 15.
The transmitted SSI value = 1 is displayed as QL
= 13.