2.1.1.
LAN
EVLunic Pro M can be connected to a router via the integrated LAN interface. The router provides a
connection to an OCPP backend over the Internet.
1 EVLunic Pro M
2 Router
3 Internet
4 OCPP backend
Connection: Ethernet1-Anschluss (LSA+®)
Via the LAN interface, EVLunic Pro M can also be connected to other charging stations, whereby a
charging network can be realized.
Information
The Ethernet2 connection X3 (RJ45) is for diagnose purposes (debugging) only
and may not be used to connect to a network.
The Ethernet1 connection X4 (LSA+®) and the Ethernet2 connection X3 (RJ45)
are connected in parallel on the PCB and cannot be used at the same time! The
connection that is not used must be unplugged from the charging station.