To adapt and delete the specific configurations, proceed as follows:
1.
Open the configuration file with a text editor.
2.
Adapt the following entries:
►
AmountConnectors=[x]
The number of charging stations in the charging network must be adapted here.
3.
Delete the following entries completely:
►
ChargeBoxIdentity=[xxx]
►
Connect2ConnectorSerial[x]=[xxx]
►
HOTSPOT_SSID=[xxx]
►
HOTSPOT_KEY=[xxx]
4.
Save the file.
Information
By deleting all
Connect2ConnectorSerial
entries, the charging station automatically searches for
other charging stations in the charging network. As many charging stations are searched as specified
under
AmountConnectors
.
Adapt configuration (optional)
If necessary, the configuration can be adapted manually. Each of the listed settings can be adapted by
editing the value to the right of the equal sign "=".
Example of a possible adaptation of the configuration
Initial configuration
Adapted configuration
AuthorizationEnabled
=true
AuthorizationEnabled
=false
Information
Invalid settings will not be applied.