The recovery key must be kept safe for the entire life of the product!
3.4.
Enabling the DHCP server
To simplify the setup of a charging network, the master charging station can be configured as a DHCP
server. This function is required for the network configuration when the master and one slave are
connected directly or when a network connection is implemented via switch.
The DHCP server of the master charging station is deactivated in the delivery state and can be activated
via the configuration in the web interface.
3.5.
Configuration in series via USB stick
Several EVLunic Pro M can be configured with the same settings. For this purpose, the configuration of
one EVLunic Pro M is saved on a USB stick and then transferred to other EVLunic Pro M.
Preparation
The following tools are required for the configuration via USB stick:
•
An empty USB stick that is formatted to FAT32
•
A computer
Furthermore, the settings that allow the configuration to be read out and imported must be enabled in
the web interface of the charging station (under Configuration > Device):
•
"Allow USB init": Allows the configuration to be read out. This setting must be activated on the
charging station that provides the configuration.
•
"Allow USB config": Allows the configuration to be imported. This setting must be activated on the
charging station to which the configuration is transferred.
Required steps
The following steps are required in order to transfer the configuration of one EVLunic Pro M to
additional EVLunic Pro M:
•
Create configuration
•
Read out configuration
•
Adapt configuration file
•
Import configuration