Information
If no OCPP backend is used, the "FirstLocal" authorization mode must be set for authorization to be
active.
*) The first 1000 RFID cards are relayed from the OCPP backend to the master charging station where
they are stored locally. If the connection to the higher-level OCPP backend fails, the master charging
station authorizes these stored RFID cards throughout the network until the connection is
reestablished.
4.2.2.
Displays and signals
During RFID authorization, the charging station can display different light patterns on the LED bar and
emit acoustic signals.
LED bar
Display
Description
Flashing green (every 3 seconds)
Authorization is done correctly.
Flashing blue (every 3 seconds)
The charging station is waiting for authorization
to enable a charging process. Authorization
necessary, either with RFID card or by an external
input.
Illuminated orange (once)
The RFID card is invalid.
Acoustic signals
Signal
Description
Single tone
RFID card has been read.
Rising tone sequence
RFID card has been accepted.
Falling tone sequence
RFID card has been rejected (no authorization).
The charging station can also display a text concerning the RFID authorization, e.g. "accepted card". This
text can be customized via the web interface.
4.2.3.
RFID authorization without OCPP backend connection
The following options are available for managing RFID cards:
•
At the RFID reader of the charging station
•
In the web interface
Managing RFID cards at the RFID reader
Both the master RFID card and all slave RFID cards can be taught in directly at the RFID reader of the
charging station. To teach in an RFID card, no charging session may be active and no vehicle may be
plugged into the charging station.