Endura AZ40 | Oxygen and carbon monoxide equivalent (COe) analyzer |
COM/AZ40/MOD–EN Rev. A
11
A.1.7 Media card diagnostics
A.1.8 Relay state diagnostics
A.1.9 Alarm state diagnostics
A.2 Digital outputs
A.2.1 Alarm acknowledgement
A.3 Read-only, single precision float
A.3.1 Measurement values
See engineering ranges table – Section A.13, page 17.
A.3.2 Measurement range limits
A.3.3 Sensor signals view – heater signals view page 1
A.3.4 Sensor signals view – oxygen signals view page 2
MODBUS coil
Description
67
Media device unit fitted
68
Media online
69
Media logging enabled
MODBUS coil
Description
70
Relay 1 state
71
Relay 2 state
72
Relay 3 state
73
Relay 4 state
74
Relay 5 state
75
Relay 6 state
MODBUS coil
Description
76
Alarm 1 state
77
Alarm 2 state
78
Alarm 3 state
79
Alarm 4 state
80
Alarm 5 state
81
Alarm 6 state
82
Alarm 7 state
83
Alarm 8 state
MODBUS coil
Description
0
Alarm 1 acknowledge state
1
Alarm 2 acknowledge state
2
Alarm 3 acknowledge state
3
Alarm 4 acknowledge state
4
Alarm 5 acknowledge state
5
Alarm 6 acknowledge state
6
Alarm 7 acknowledge state
7
Alarm 8 acknowledge state
8
Acknowledge alarm 1
9
Acknowledge alarm 2
10
Acknowledge alarm 3
11
Acknowledge alarm 4
12
Acknowledge alarm 5
13
Acknowledge alarm 6
14
Acknowledge alarm 7
15
Acknowledge alarm 8
MODBUS address
Description
30000
Oxygen concentration value
30002
COe concentration value
30004
Inlet temperature value
30006
Outlet temperature value
30008
Outlet / Inlet temperature value
30010
Efficiency value
MODBUS address
Description
30012
Oxygen concentration
– Engineering range high
30014
Oxygen concentration
– Engineering range low
30016
COe concentration
– Engineering range low
30018
COe concentration
– Engineering range high
30020
Inlet temperature
– Engineering range high
30022
Inlet temperature
– Engineering range low
30024
Outlet temperature
– Engineering range high
30026
Outlet temperature
– Engineering range low
30028
Outlet – Inlet temperature – Engineering range high
30030
Outlet – Inlet temperature – Engineering range low
30032
Efficiency
– Engineering range high
30034
Efficiency
– Engineering range low
MODBUS address
Description
30036
View 1 – Flange block temperature
30038
View 2 – Flange block proportional control (%)
30040
View 3 – Sensor cold junction temperature
30042
View 4 – Oxygen heater current
30044
View 5 – Oxygen heater voltage
30046
View 6 – Oxygen heater power
30048
View 7 – COe block temperature
30050
View 8 – COe block proportional control (%)
MODBUS address
Description
30052
View 1 – Oxygen concentration (%)
30054
View 2 – Oxygen sensor output (mV)
30056
View 3 – Oxygen sensor last zero
30058
View 4 – Oxygen sensor last span
30060
View 5 – Oxygen sensor active zero
30062
View 6 – Oxygen sensor active span
30064
View 7 – Reserved
30066
View 8 – Reserved