14
COM/AZ40/MOD–EN Rev. A
| Endura AZ40 | Oxygen and carbon monoxide equivalent (COe) analyzer
A.11 Writable 8 bits
A.11.1 Measurement units
A.11.2 Operator page templates
A.11.3 Data view / log enables
MODBUS address
Description
Valid range
43000
Transmitter – temperature units
4 – Deg.C
5 – Deg. F
43001
Sensor 1 – filter type
0 – Off
4 – Sliding average
1 – Minimum value
2 – Maximum value
3 – Average value
43002
Fuel type
0 – Gas
4 – Bituminous
1 – Light oil
5 – Lignite
2 – Heavy oil
3 – Anthracite
43003
COe units
2 – %
3 – ppm
43004
Inlet thermocouple types
0 – None
4 – Type K
8 – Type T
1 – Type B
5 – Type N
2 – Type E
6 – Type R
3 – Type J
7 – Type S
43005
Outlet thermocouple types
43006
Efficiency calculation
0 – Disabled
1 – Enabled
43007
Blowback interval
0 – Off
1 – 24 hours
43008
Reserved
43009
Scheduled calibration frequency units
1 – Off
1 – Daily
2 – Weekly
3 – Monthly
43010
Scheduled calibration frequency
0 – 30 (days)
43011
Scheduled calibration frequency
0 – 7 (weeks)
43012
Scheduled calibration frequency
(months)
0 = 1
4 = 6
1 = 2
5 = 12
2 = 3
3 = 4
MODBUS address
Description
Valid range
43013
Operator page 2 template
0 – Off
1 – Oxygen
3 – Temperature
2 – Combustibles
4 – Efficiency
43014
Operator page 3 template
43015
Operator page 4 template
43016
Operator page 5 template
MODBUS address
Description
Valid range
43017
Diagnostics view
0 – Disabled
1 – Enabled
43018
Signals view
43019
Chart view
43020
Alarm view
43021
Analog output view
43022
Calibration log
43023
Alarm log
43024
Audit log
43025
Diagnostics log