Design and commissioning tools
Drives Window
PC program for Commissioning and maintenance
under Windows
®
platform for:
Parameter setting
Error detection
Trending - capability of all signals
Data logger
Fault logger
Local operation (Drives Panel)
CDP 312
removable control and display panel
with plain text display for:
Parameter setting
Error detection
Parameter uploading and downloading
Local operation
Monitoring functions
Self-test
Non-volatile fault memory
Motor protection
In the event of:
speed feedback error
overtemperature
overload
overspeed
zero speed
armature-circuit overcurrent
armature-circuit ripples
armature-circuit overvoltage
minimum field current
field overcurrent
Power converter protection
overtemperature
software errors (watchdog function)
Incorrect supply protection
mains interruption
auxiliary supply undervoltage
incorrect mains phase sequence (only inform.)
Basic functions
All units are provided with the same digital
control board and software. The DCS 600 Multi-
Drive flexibility allows the user to configure
functions of the drive easily suitable for different
applications. Functions of the DCS 600 Multi-
Drive are normally activated by selecting a cer-
tain value to the function activation parameter.
The basic software includes the following op-
tions:
Processing the speed reference value with
speed ramp generator (S-ramp capability, ac-
cel/decel ramp)
Processing the speed feedback
Speed controller
Torque reference processing (ramp function)
Current regulator
Selectable field weakening for constant pow-
er-applications
Automatic/manual field reversal
Automatic adjustment for armature-circuit con-
troller
Speed monitor
Drive control logic
Remote/local operation
Emergency stop
Electronic circuits are not sensitive to line
phase sequence
Electrical and mechanical brake control
Motor overload sensing
Dual field supply software
Programmable analogue outputs
Field supply
Master-follower
Controlling and operating
via
I/O terminals
analogue and digital inputs and outputs
via
communication data bus
e.g.: Profibus, Modbus Plus, AF100 etc.
via
MMI
(man-machine interface)
Outputting:
Alarms
Errors
Status information
Parameter setting
Controlling the drive
II F 1-2