19
Electromagnetic Flowmeter COPA-XT
Submenu/Parameter
Entry Type
Comments
Four character name for the user configurable units.
Programmable units for mass (with density) or
volume (without density) flowrate units
from table/numeric
Exit from submenu
All detected errors (Error 0-9, A, B, C) are stored.
The error register can be cleared with ENTER.
Alarm limit, range 0 - 105 % of the flow range setting.
Alarm limit, range 0 - 105 % of the flow range setting.
Exit from submenu
Current output during an alarm condition, can be set to
0 % or 105 %
Error 3 Flowrate > 105 %, always set to 22 mA %
Exit from submenu
Instrument address: 0-99
If multiple instruments are connected to a single bus, then each
instrument must have a unique address.
Activate the HART-Communication:
HART or off
from table/numeric
Exit from submenu
Function test of current output, enter value in mA
Function test of pulse output 1 Hz
For detailed information see Sect. 6.2
Unit name
kga /s /min /h
Prog. Units
Without Density
Submenu
Alarm
C/CE
ENTER
Error Register
0 . . . 3 . . .
Max-Alarm
105 %
Min-Alarm
10 %
Submenu
Current Output
C/CE
ENTER
Iout at Alarm
105 %
Submenu
Data Link
C/CE
ENTER
Instr. Address
0
Communication
HART
Submenu
Function Test
C/CE
ENTER
Function Test
Iout