TABLE 1-4. METER CAPACITY VALUES
Meter
Size
Meter
Capacity
*
Flow Ranges
0 to Value Tabulated
Capacity Setting
( If not specified by
customer)
Minimum
Maximum
inch
mm
gpm
gpm
L/min
gpm
L/min
gpm
L/min
1
25
52.83
2.65
10.0
52.8
200.0
16.00
60.0
1
1
⁄
2
40
158.5
7.93
30.0
158.0
600.0
50.0
200
m
3
/h
m
3
/h
m
3
/h
2
50
264.1
13.3
3.0
264.0
60.0
80.0
20.0
3
80
792.5
39.7
9.0
792.0
180.0
250
60.0
4
100
1056
52.9
12.0
1056.0
240.0
320
80.0
6
150
2641
133
30.0
2641.0
600.0
800
200
8
200
4755
238
54.0
4755.0
1080.0
1500
300
10
250
7925
397
90.0
7925.0
1800.0
2500
550
12
300
10567
528
120.0
10567
2400
3500
800
* Each meter is calibrated to determine its flow capacity at a given velocity, which has been
established as 32.808 ft/s (10 m/s) for the meter capacity (Range DN). The meter capacity expressed
in gpm is recorded on the meter nameplate.
The meter capacity is the base upon which maximum and minimum limits for range settings and
outputs are established.
Flow velocity can be determined as follows:
Meter Capacity:
Flow Velocity (ft/s) = (Operating gpm x 32.808)/Meter Capacity
NOTE
The maximum meter flow range is a function of the signal converter used. The maxi-
mum flow range can not exceed the meter capacity.