![ABB ACS880-34 Hardware Manual Download Page 75](http://html.mh-extra.com/html/abb/acs880-34/acs880-34_hardware-manual_2653075.webp)
Guidelines for planning the electrical installation 75
Connecting a motor temperature sensor to the drive I/O
WARNING!
IEC 60664 and IEC 61800-5-1 require double or reinforced
insulation between live parts and the surface of accessible parts of electrical
equipment which are either non-conductive or conductive but not connected to
the protective earth.
To connect a motor temperature sensor and other similar components to the drive, you
have four alternatives:
1. If there is double or reinforced insulation between the sensor and the live parts of the
motor, you can connect the sensor directly to the analog/digital inputs of the drive.
2. If there is basic insulation between the sensor and the live parts of the motor, you can
connect the sensor to the analog/digital inputs of the drive if all circuits connected to
the drive’s digital and analog inputs (typically extra-low voltage circuits) are protected
against contact and insulated with basic insulation from other low-voltage circuits. The
insulation must be rated for the same voltage level as the drive main circuit. Note that
extra-low voltage circuits (such as 24 V DC) typically do not meet these requirements.
3. You can connect the sensor to the drive via an option module.The sensor and the
module must form a double or reinforced insulation between the motor live parts and
the drive control unit. See section
Connection of motor temperature sensor to the drive
(page
).
4. You can connect the sensor to a digital input of the drive via a relay (internal option or
customer’s external relay). The sensor and the relay must form a double or reinforced
insulation between the motor live parts and the drive control unit. See section
Connection of motor temperature sensor to the drive via a relay
Connection of motor temperature sensor to the drive via an option
module
This table shows:
•
option module types that you can use for the motor temperature sensor connection
•
insulation or isolation level that each option module forms between its temperature
sensor connector and other connectors
•
temperature sensor types that you can connect to each option module
•
temperature sensor insulation requirement in order to form, together with the
insulation of the option module, a double or reinforced insulation between the motor
live parts and the drive control unit.
Option module
Temperature sensor
type
Temperature sensor
insulation requirement
Type
Insulation/Isolation
PTC
KTY
Pt100,
Pt1000
FIO-11
Galvanic isolation between sensor
connector and other connectors
(including drive control unit connector)
-
X
X
Reinforced insulation
FEN-xx Galvanic isolation between sensor
connector and other connectors
(including drive control unit connector)
X
X
-
Reinforced insulation
Summary of Contents for ACS880-34
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 34 drive modules 132 to 400 kW 200 to 450 hp Hardware manual ...
Page 4: ......
Page 14: ...14 ...
Page 22: ...22 Safety instructions ...
Page 28: ...28 Introduction to the manual ...
Page 42: ...42 Operation principle and hardware description ...
Page 118: ...118 External control unit ...
Page 140: ...140 Installation example with full cabling panels option H381 M8 16 Hex 2 5 4 3 1 1 1 1 2 6 7 ...
Page 152: ...152 Installation checklist ...
Page 156: ...156 Start up ...
Page 158: ...158 Fault tracing ...
Page 174: ...174 Maintenance ...
Page 202: ...202 Technical data EU Declaration of Conformity Machinery Directive ...
Page 204: ...204 Technical data ...
Page 206: ...206 Dimension drawings Standard configuration 3AXD50000038012 ...
Page 208: ...208 Dimension drawings Drive module with options 0B051 H356 0H371 3AXD50000038012 ...
Page 209: ...Dimension drawings 209 Configuration with option H381 3AXD50000323210 ...
Page 210: ...210 Dimension drawings LCL filter module 3AXD50000206162 ...
Page 214: ...214 Dimension drawings External control unit 3axd50000011687 ...
Page 238: ...238 Resistor braking ...
Page 242: ...242 du dt and sine filters ...
Page 256: ...Contact us www abb com drives www abb com drivespartners 3AXD50000035191 Rev B EN 2018 09 28 ...