![ABB ACS880-34 Hardware Manual Download Page 171](http://html.mh-extra.com/html/abb/acs880-34/acs880-34_hardware-manual_2653171.webp)
Maintenance 171
Replacing the LCL filter module with H381
1. See
Step-by-step drawings for an installation example of standard drive configuration
in Rittal TS 8 800 mm wide cabinet
•
Disconnect the LCL filter module from the drive module.
•
Undo the screws that attach the LCL filter module to the cabinet frame.
•
Attach the extraction ramp to the cabinet base with two screws.
2. To prevent the LCL filter module from falling, attach its top lifting lugs with chains to
the cabinet frame.
3. Pull the LCL filter module carefully out of the cabinet preferably with help from another
person.
4. Install the new module in reverse order.
Capacitors
The drive intermediate circuit employs several electrolytic capacitors. Their lifespan
depends on the operating time of the drive, loading and ambient temperature. The lifespan
of the capacitor can be prolonged by lowering the ambient temperature.
It is not possible to predict a capacitor failure. The capacitor failure is usually followed by
damage to the unit and an input cable fuse failure, or a fault trip. Contact ABB if a
capacitor failure is suspected. Replacements are available from ABB. Do not use other
than ABB specified spare parts.
Reforming the capacitors
If the drive module has been stored for one year or more, reform the capacitors. See page
for information on finding out the manufacturing date. For the reforming instructions,
see
Converter modules with electrolytic DC capacitors in the DC link, capacitor reforming
instructions
(3BFE64059629 [English]).
Control panel
Replacing the control panel battery
1. Turn the lid on the back of the panel counter-clockwise until the lid opens.
2. Replace the battery with a new CR2032 battery.
3. Put the lid back and tighten it by turning it clockwise.
4. Dispose of the old battery according to local disposal rules or applicable laws.
Summary of Contents for ACS880-34
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 34 drive modules 132 to 400 kW 200 to 450 hp Hardware manual ...
Page 4: ......
Page 14: ...14 ...
Page 22: ...22 Safety instructions ...
Page 28: ...28 Introduction to the manual ...
Page 42: ...42 Operation principle and hardware description ...
Page 118: ...118 External control unit ...
Page 140: ...140 Installation example with full cabling panels option H381 M8 16 Hex 2 5 4 3 1 1 1 1 2 6 7 ...
Page 152: ...152 Installation checklist ...
Page 156: ...156 Start up ...
Page 158: ...158 Fault tracing ...
Page 174: ...174 Maintenance ...
Page 202: ...202 Technical data EU Declaration of Conformity Machinery Directive ...
Page 204: ...204 Technical data ...
Page 206: ...206 Dimension drawings Standard configuration 3AXD50000038012 ...
Page 208: ...208 Dimension drawings Drive module with options 0B051 H356 0H371 3AXD50000038012 ...
Page 209: ...Dimension drawings 209 Configuration with option H381 3AXD50000323210 ...
Page 210: ...210 Dimension drawings LCL filter module 3AXD50000206162 ...
Page 214: ...214 Dimension drawings External control unit 3axd50000011687 ...
Page 238: ...238 Resistor braking ...
Page 242: ...242 du dt and sine filters ...
Page 256: ...Contact us www abb com drives www abb com drivespartners 3AXD50000035191 Rev B EN 2018 09 28 ...