Electrical installation
59
DC connection
The UDC+ and UDC– terminals are intended for common DC configurations of a
number of ACS850 drives, allowing regenerative energy from one drive to be utilised
by the other drives in motoring mode.
One or more drives are connected to the AC supply depending on the power
requirement. In case two or more drives are connected to the AC supply, each AC
connection must be equipped with a mains choke to ensure even current distribution
between the rectifiers. The diagram below shows two configuration examples.
AC supply
M
3~
~
~
M
3~
M
3~
AC supply
Mains chokes
~
~
~
~
UDC+
UDC–
UDC+
UDC–
M
3~
~
~
UDC+
UDC–
UDC+
UDC–
M
3~
~
~
UDC+
UDC–
M
3~
~
~
UDC+
UDC–
Summary of Contents for ACS850 series
Page 1: ...ACS850 Hardware Manual ACS850 04 Drive Modules 1 1 to 45 kW...
Page 2: ......
Page 4: ......
Page 14: ...Table of contents 14...
Page 20: ...About this manual 20...
Page 32: ...Planning the cabinet assembly 32...
Page 38: ...Mechanical installation 38...
Page 48: ...Planning the electrical installation 48...
Page 50: ...Electrical installation 50 1 2 3 4 5...
Page 68: ...Electrical installation 68...
Page 76: ...Maintenance 76...
Page 102: ...du dt and common mode filtering 102...
Page 108: ...Dimension drawings 108 Frame size A...
Page 109: ...Dimension drawings 109 Frame size B...
Page 110: ...Dimension drawings 110 Frame size C...
Page 111: ...Dimension drawings 111 Frame size D...
Page 113: ...Dimension drawings 113 EMC filters type JFI x1 JFI A1...
Page 114: ...Dimension drawings 114 JFI B1...
Page 115: ...Dimension drawings 115 EMC filters type JFI 0x...
Page 117: ...Dimension drawings 117 Braking resistors type JBR xx...