Resistor braking
122
Optional brake chopper and resistor(s) for the ACS800-02/U2, the
ACS800-04/U4 and the ACS800-07/U7
ACS 800 type
Frame
size
Braking power of the chopper and the
drive
Brake resistor(s)
5/60 s
P
br5
(kW)
10/60 s
P
br10
(kW)
30/60 s
P
br30
(kW)
P
brcont
(kW)
Type
R
(ohm)
E
R
(kJ)
P
Rcont
(kW)
230 V units
-0080-2
R7
68
68
68
54
SAFUR 160F380
1.78
3600
9
-0100-2
R7
83
83
83
54
SAFUR 160F380
1.78
3600
9
-0120-2
R7
105
67
60
40
2xSAFUR200F500
1.35
10800
27
-0140-2
R8
135
135
135
84
2xSAFUR160F380
0.89
7200
18
-0170-2
R8
135
135
135
84
2xSAFUR160F380
0.89
7200
18
-0210-2
R8
165
165
165
98
2xSAFUR160F380
0.89
7200
18
-0230-2
R8
165
165
165
113
2xSAFUR160F380
0.89
7200
18
-0260-2
R8
223
170
125
64
4xSAFUR160F380
0.45
14400
36
-0300-2
R8
223
170
125
64
4xSAFUR160F380
0.45
14400
36
400 V units
-0070-3
R6
-
-
-
68
SAFUR80F500
6
2400
6
-0100-3
R6
-
-
-
83
SAFUR125F500
4
3600
9
-0120-3
R6
-
-
-
113
SAFUR125F500
4
3600
9
-0140-3
R7
135
135
100
80
SAFUR200F500
2.70
5400
13.5
-0170-3
R7
165
150
100
80
SAFUR200F500
2.70
5400
13.5
-0210-3
R7
165
150
100
80
SAFUR200F500
2.70
5400
13.5
-0260-3
R8
240
240
240
173
2XSAFUR210F575
1.70
8400
21
-0320-3
R8
300
300
300
143
2xSAFUR200F500
1.35
10800
27
-0400-3
R8
375
375
273
130
4xSAFUR125F500
1.00
14400
36
-0440-3
R8
473
355
237
120
4xSAFUR210F575
0.85
16800
42
-0490-3
R8
500
355
237
120
4xSAFUR210F575
0.85
16800
42
500 V units
-0100-5
R6
-
-
-
83
SAFUR125F500
4
3600
9
-0120-5
R6
-
-
-
113
SAFUR125F500
4
3600
9
-0140-5
R6
-
-
-
135
SAFUR125F500
4
3600
9
-0170-5
R7
165
132
2)
120
80
SAFUR200F500
2.70
5400
13.5
-0210-5
R7
198
132
2)
120
80
SAFUR200F500
2.70
5400
13.5
-0260-5
R7
198
1)
132
2)
120
80
SAFUR200F500
2.70
5400
13.5
-0270-5*
R8
240
240
240
240
2xSAFUR125F500
2.00
7200
18
-0300-5*
R8
280
280
280
280
2xSAFUR125F500
2.00
7200
18
-0320-5
R8
300
300
300
300
2xSAFUR125F500
2.00
7200
18
-0400-5
R8
375
375
375
234
2XSAFUR210F575
1.70
8400
21
-0440-5
R8
473
473
450
195
2xSAFUR200F500
1.35
10800
27
-0490-5
R8
480
480
470
210
2xSAFUR200F500
1.35
10800
27
-0550-5
R8
600
400
4)
300
170
4xSAFUR125F500
1.00
14400
36
-0610-5
R8
600
3)
400
4)
300
170
4xSAFUR125F500
1.00
14400
36
690 V units
-0070-7
R6
-
-
-
45
SAFUR90F575
8.00
1800
4.5
-0100-7
R6
-
-
-
55
SAFUR80F500
6.00
2400
6
-0120-7
R6
-
-
-
75
SAFUR80F500
6.00
2400
6
-0140-7
R7
125
5)
110
90
75
SAFUR80F500
6.00
2400
6
-0170-7
R7
125
6)
110
90
75
SAFUR80F500
6.00
2400
6
-0210-7
R7
125
6)
110
90
75
SAFUR80F500
6.00
2400
6
-0260-7
R7
135
7)
120
100
80
SAFUR80F500
6.00
2400
6
-0320-7
R8
300
300
300
260
SAFUR200F500
2.70
5400
13.5
-0400-7
R8
375
375
375
375
SAFUR200F500
2.70
5400
13.5
-0440-7
R8
430
430
430
385
SAFUR200F500
2.70
5400
13.5
-0490-7
R8
550
400
315
225
2xSAFUR125F500
2.00
7200
18
-0550-7
R8
550
400
315
225
2xSAFUR125F500
2.00
7200
18
-0610-7
R8
550
400
315
225
2xSAFUR125F500
2.00
7200
18
PDM code 00096931-G
Summary of Contents for ACS800-02
Page 1: ...ACS800 Hardware Manual ACS800 02 Drives 45 to 500 kW ACS800 U2 Drives 60 to 600 HP ...
Page 4: ......
Page 10: ...Safety instructions 10 ...
Page 20: ...About this manual 20 ...
Page 26: ...The ACS800 02 U2 26 ...
Page 42: ...Planning the electrical installation 42 ...
Page 76: ...Installation checklist 76 ...
Page 106: ...Technical data 106 ...
Page 108: ...Dimensional drawings 108 Frame size R7 US gland conduit plate 64579746 H ...
Page 109: ...Dimensional drawings 109 Frame size R8 3AFE 64564161 D US gland conduit plate ...
Page 110: ...Dimensional drawings 110 Frame size R7 with enclosure extension bottom entry 64625942 1 2 B ...
Page 111: ...Dimensional drawings 111 64625942 2 2 C ...
Page 112: ...Dimensional drawings 112 Frame size R7 with enclosure extension top entry 64626264 1 2 C ...
Page 113: ...Dimensional drawings 113 64626264 2 2 C ...
Page 115: ...Dimensional drawings 115 3AFE 64626388 2 2 B ...
Page 116: ...Dimensional drawings 116 Frame size R8 with enclosure extension top entry 3AFE 64626370 1 2 C ...
Page 117: ...Dimensional drawings 117 3AFE 64626370 2 2 C ...
Page 118: ...Dimensional drawings 118 ...
Page 127: ......