Selecting and routing the brake resistor cables
Use a shielded cable with the conductor size specified in section Terminal and
entry data for the power cables on page
Terminal and entry data for the power
.
Minimizing electromagnetic interference
Follow these rules in order to minimize electromagnetic interference caused by
the rapid current changes in the resistor cables:
•
Install the cables away from other cable routes.
•
Avoid long parallel runs with other cables. The minimum parallel cabling
separation distance should be 0.3 meters.
•
Cross the other cables at right angles.
•
Keep the cable as short as possible in order to minimize the radiated emissions
and stress on chopper IGBTs. The longer the cable the higher the radiated
emissions, inductive load and voltage peaks over the IGBT semiconductors of
the brake chopper.
Note: ABB has not verified that the EMC requirements are fulfilled with external
user-defined brake resistors and cabling. The EMC compliance of the complete
installation must be considered by the customer.
Maximum cable length
The maximum length of the resistor cable(s) is 10 m (33 ft).
Placing the brake resistor
Install the resistors outside the drive in a place where they will cool.
Arrange the cooling of the resistor in a way that:
•
no danger of overheating is caused to the resistor or nearby materials
•
the temperature of the room the resistor is located in does not exceed the
allowed maximum.
Supply the resistor with cooling air/water according to the resistor manufacturer’s
instructions.
WARNING!
The materials near the brake resistor must be non-flammable. The surface
temperature of the resistor is high. Air flowing from the resistor is of
hundreds of degrees Celsius. If the exhaust vents are connected to a
ventilation system, make sure that the material withstands high
temperatures. Protect the resistor against contact.
Resistor braking 403
Summary of Contents for ACS580 Series
Page 1: ...ABB GENERAL PURPOSE DRIVES ACS580 01 drives Hardware manual...
Page 2: ......
Page 4: ......
Page 19: ...Further information Table of contents 19...
Page 20: ...20...
Page 34: ...34...
Page 58: ...58...
Page 128: ...128...
Page 163: ...R5 4 6 11 11 10 4 3 5 7 8 9 0 5 0 6 N m 0 4 lbf ft 8 4 Electrical installation Global IEC 163...
Page 207: ...R6 R9 11 11 7 3 9 5 10 6 4 R6 R9 0 4 lbf ft Electrical installation North America 207...
Page 214: ...214...
Page 236: ...236...
Page 240: ...240...
Page 242: ...242...
Page 258: ...3a 3b 3c 4 5 7 6 2d 2a 2b 2c 258 Maintenance...
Page 364: ...Frame R1 IP21 UL Type 1 3AXD10000601652 364 Dimension drawings...
Page 365: ...Frame R1 IP55 UL Type 12 3AXD10000601699 Dimension drawings 365...
Page 366: ...Frame R1 IP55 F278 UL Type 12 366 Dimension drawings...
Page 367: ...Frame R1 IP66 UL Type 4X B066 3AXD50001012694 Dimension drawings 367...
Page 368: ...Frame R1 IP66 UL Type 4X B063 3AXD50001012694 368 Dimension drawings...
Page 369: ...Frame R1 IP66 UL Type 4X C193 3AXD50001012694 Dimension drawings 369...
Page 370: ...Frame R2 IP21 UL Type 1 3AXD10000602398 370 Dimension drawings...
Page 371: ...Frame R2 IP55 UL Type 12 3AXD10000602401 Dimension drawings 371...
Page 372: ...Frame R2 IP55 F278 UL Type 12 372 Dimension drawings...
Page 373: ...Frame R2 IP66 UL Type 4X B066 3AXD50000999286 Dimension drawings 373...
Page 374: ...Frame R2 IP66 UL Type 4X B063 3AXD50000999286 374 Dimension drawings...
Page 375: ...Frame R2 IP66 UL Type 4X C193 3AXD50000999286 Dimension drawings 375...
Page 376: ...Frame R3 IP21 UL Type 1 3AXD10000602466 376 Dimension drawings...
Page 377: ...Frame R3 IP55 UL Type 12 3AXD10000602519 Dimension drawings 377...
Page 378: ...Frame R3 IP55 E223 UL Type 12 378 Dimension drawings...
Page 379: ...Frame R3 IP55 F278 F316 UL Type 12 Dimension drawings 379...
Page 380: ...Frame R3 IP66 UL Type 4X B066 3AXD50001013059 380 Dimension drawings...
Page 381: ...Frame R3 IP66 UL Type 4X B063 3AXD50001013059 Dimension drawings 381...
Page 382: ...Frame R3 IP66 UL Type 4X C193 3AXD50001013059 382 Dimension drawings...
Page 383: ...Frame R4 IP21 UL Type 1 3AXD10001330082 Dimension drawings 383...
Page 384: ...Frame R4 IP55 UL Type 12 3AXD10001330271 384 Dimension drawings...
Page 385: ...Frame R4 IP55 E223 UL Type 12 3AXD10001373680 Dimension drawings 385...
Page 386: ...Frame R4 IP55 F278 F316 UL Type 12 3AXD10001373680 386 Dimension drawings...
Page 387: ...Frame R5 IP21 UL Type 1 3AXD10000427933 Dimension drawings 387...
Page 388: ...Frame R5 IP55 UL Type 12 3AXD10000386017 388 Dimension drawings...
Page 389: ...Frame R5 IP55 E223 UL Type 12 Dimension drawings 389...
Page 390: ...Frame R5 IP55 F278 F316 UL Type 12 390 Dimension drawings...
Page 391: ...Frame R6 IP21 UL Type 1 3AXD10000258705 Dimension drawings 391...
Page 392: ...Frame R6 IP55 UL Type 12 3AXD10000330667 392 Dimension drawings...
Page 393: ...Frame R7 IP21 UL Type 1 3AXD10000258995 Dimension drawings 393...
Page 394: ...Frame R7 IP55 UL Type 12 3AXD10000330932 394 Dimension drawings...
Page 395: ...Frame R8 IP21 UL Type 1 3AXD10000287670 Dimension drawings 395...
Page 396: ...Frame R8 IP55 UL Type 12 3AXD10000332446 396 Dimension drawings...
Page 397: ...Frame R9 IP21 UL Type 1 3AXD10000287428 Dimension drawings 397...
Page 398: ...Frame R9 IP55 UL Type 12 3AXD10000334310 398 Dimension drawings...
Page 459: ...Optional I O extension and adapter modules 459...
Page 460: ...460...