5.8 Demand
General
Interval length
Storing periods
The demand functionality is used to measure and store the maximum and mini-
mum demands of different quantities in the meter. Time is divided into
intervals of a certain length in which the mean values of a set of selected
quantities are measured.
Demand can be configured via Modbus and EQ-bus communication or via
the buttons on the meter.
Note
–
Before any demand values can be stored, time/date must be set.
Changing time/date will store the current period and start a new one.
If a power fail occurs that lasts over the end of an ongoing period, the period will
be stored when the meter powers up again and a new period will start. If date/time
is not set when the meter powers up again, demand will enter a waiting state until
time/date is set.
The interval lengths for demand can be one of the following: 1, 2, 5, 10, 15,
20, 30, 60 minutes.
When the last interval of an ongoing period has finished, the maximum
and/or minimum values are stored and a new period starts.
The length of a demand period can be a day, a week or a month.
Demand has 50 channels which can be configured individually. Each channel
can store up to 200 periods. A stored period contains the demand value, the
date/time of the period and the date/time of the interval when the demand value
was mea-sured. All channels use the same interval, subinterval and period
length. Individ-ual channel parameters are type of demand which have the four
choices maxi-mum, minimum, maximum sliding or minimum sliding and the
number of the demand with the three choices first, second or third (max/min).
The period/interval date and time is stored as end of period/interval. For
instance, if a period starts 2010.01.01 00:00.00 and ends 2010.01.02 00:00.00,
then the stored period will be 2010.01.02 00:00.00.
If there is no free memory space available, the oldest period will be erased
to make room for the most recent one.
Stored periods can be read via communication or directly on the display.
An ongoing period can be ended and a new one started by sending a “freeze de-
mand” via communication.
It is also possible to erase all stored periods by sending a “Reset Demand”
com-mand via communication.
If the time is set backward within an interval the calculation of demand for that
interval is restarted if the channel is configured to store a maximum value (as the
Summary of Contents for A43
Page 1: ...A43 A44 User Manual ...
Page 40: ...Meter Settings A43 A44 40 2CMC48001M0201 User Manual Revision C ...
Page 55: ...Technical Description 2CMC48001M0201 55 A43 A44 Revision C User Manual ...
Page 58: ...Technical Description A43 A44 58 2CMC48001M0201 User Manual Revision C ...
Page 61: ...Technical Description 2CMC48001M0201 61 A43 A44 Revision C User Manual ...
Page 75: ...Technical Description 2CMC48001M0201 75 A43 A44 Revision C User Manual ...
Page 84: ...Measurement Methods A43 A44 84 2CMC48001M0201 User Manual Revision C ...
Page 91: ...Measurement Methods 2CMC48001M0201 91 A43 A44 Revision C User Manual ...
Page 95: ...Measurement Methods 2CMC48001M0201 95 A43 A44 Revision C User Manual ...
Page 102: ...Communication with Modbus A43 A44 102 2CMC48001M0201 User Manual Revision C ...
Page 107: ...Communication with Modbus 2CMC48001M0201 107 A43 A44 Revision C User Manual ...
Page 131: ...Communication with Modbus 2CMC48001M0201 131 A43 A44 Revision C User Manual ...
Page 147: ...Communication with Modbus 2CMC48001M0201 147 A43 A44 Revision C User Manual ...
Page 154: ...Communication with Modbus A43 A44 154 2CMC48001M0201 User Manual Revision C ...
Page 157: ...Communication with Modbus 2CMC48001M0201 157 A43 A44 Revision C User Manual ...
Page 161: ...Communication with Modbus 2CMC48001M0201 161 A43 A44 Revision C User Manual ...
Page 166: ...Communication with Modbus A43 A44 166 2CMC48001M0201 User Manual Revision C ...
Page 180: ...Communication with M Bus A43 A44 180 2CMC48001M0201 User Manual Revision C ...
Page 182: ...Communication with M Bus A43 A44 182 2CMC48001M0201 User Manual Revision C ...
Page 188: ...Communication with M Bus A43 A44 188 2CMC48001M0201 User Manual Revision C ...
Page 195: ...Communication with M Bus 2CMC48001M0201 195 A43 A44 Revision C User Manual ...
Page 254: ...Communication with M Bus A43 A44 254 2CMC48001M0201 User Manual Revision C ...
Page 257: ...Communication with M Bus 2CMC48001M0201 257 A43 A44 Revision C User Manual ...