![ABB A43 User Manual Download Page 36](http://html.mh-extra.com/html/abb/a43/a43_user-manual_4297036.webp)
Meter Settings
A43/A44
36
2CMC48001M0201
User Manual
Revision: C
I/O
Available choices
1 static I/O
• Alarm out
• Communication out (Comm.out on display)
• Pulse out (Pul.out on display)
• Tariff out
1
• Always on
• Always off
1.
This choice makes it possible to control outputs by time.
2.
I/O 1 and I/O 2 are set to static output by default.I/O 3 and 4 are set to static
input by default and cannot be configured. I/O 3 and I/O 4 are not shown in
the display.
3.
This choice makes it possible to control fixed I/O outputs by time and thus
only available in gold meters.
4.1.7 Setting Alarm
To set the alarm, perform the following steps:
1. Choose the Settings icon in the main menu, press
.
2. Choose “Alarm”, press
.
3. The display will show what quantity shall be measured. Depending on the
meter type, different quantities are available. See
table
and
table 4:3
for
available quantities and interval/units for the different quantities. Set the
desired quantity.
4. Press
once to get to the next menu. The display will show what level the
alarm will trigger on. Set the alarm level.
5. Press
once to get to the next menu. The display will show the time that
the measured value has to be higher than the limit set in the previous step
in order for the alarm to trigger. Set the time limit.
6. Press
once to get to the next menu.The display will show what level the
alarm will cease on.Set the alarm level.
7. Press
once to get to the next menu. The display will show the time that
the measured value has to be lower than the limit set in the previous step in
order for the alarm to cease. Set the time limit.
8. Press
once to get to the next menu.The display will show if the alarm
will be logged or not. The available values are “on” and “off”. Set logging
to on or off.
9. Press
once to get to the next menu. The display will show what output
the alarm is set on (or if no output is set). The available choices are
dependent on meter type, see
table 4:4
.
Note
–
If choosing an I/O that is not alarm configured, the option will be set to “no
output” when pressing the
button.
10.The first alarm is now fully configured. Depending on the meter type,
up to 25 alarms can be set. If your meter supports multiple alarms, use
and
to set the remaining alarms the same way as the first alarm was
configured.
Summary of Contents for A43
Page 1: ...A43 A44 User Manual ...
Page 40: ...Meter Settings A43 A44 40 2CMC48001M0201 User Manual Revision C ...
Page 55: ...Technical Description 2CMC48001M0201 55 A43 A44 Revision C User Manual ...
Page 58: ...Technical Description A43 A44 58 2CMC48001M0201 User Manual Revision C ...
Page 61: ...Technical Description 2CMC48001M0201 61 A43 A44 Revision C User Manual ...
Page 75: ...Technical Description 2CMC48001M0201 75 A43 A44 Revision C User Manual ...
Page 84: ...Measurement Methods A43 A44 84 2CMC48001M0201 User Manual Revision C ...
Page 91: ...Measurement Methods 2CMC48001M0201 91 A43 A44 Revision C User Manual ...
Page 95: ...Measurement Methods 2CMC48001M0201 95 A43 A44 Revision C User Manual ...
Page 102: ...Communication with Modbus A43 A44 102 2CMC48001M0201 User Manual Revision C ...
Page 107: ...Communication with Modbus 2CMC48001M0201 107 A43 A44 Revision C User Manual ...
Page 131: ...Communication with Modbus 2CMC48001M0201 131 A43 A44 Revision C User Manual ...
Page 147: ...Communication with Modbus 2CMC48001M0201 147 A43 A44 Revision C User Manual ...
Page 154: ...Communication with Modbus A43 A44 154 2CMC48001M0201 User Manual Revision C ...
Page 157: ...Communication with Modbus 2CMC48001M0201 157 A43 A44 Revision C User Manual ...
Page 161: ...Communication with Modbus 2CMC48001M0201 161 A43 A44 Revision C User Manual ...
Page 166: ...Communication with Modbus A43 A44 166 2CMC48001M0201 User Manual Revision C ...
Page 180: ...Communication with M Bus A43 A44 180 2CMC48001M0201 User Manual Revision C ...
Page 182: ...Communication with M Bus A43 A44 182 2CMC48001M0201 User Manual Revision C ...
Page 188: ...Communication with M Bus A43 A44 188 2CMC48001M0201 User Manual Revision C ...
Page 195: ...Communication with M Bus 2CMC48001M0201 195 A43 A44 Revision C User Manual ...
Page 254: ...Communication with M Bus A43 A44 254 2CMC48001M0201 User Manual Revision C ...
Page 257: ...Communication with M Bus 2CMC48001M0201 257 A43 A44 Revision C User Manual ...