10
10
/2
1SBC104001M1701
1
2
3
1SBC388114F0302
1
2
3
GB
F
R.. (A)
Order code /
N° d'identification
kg
–
– –
R..63 ... 260
FPTN 410 056 R1
FPTN 410 056 R0001
0.060
–
– –
R..315 ... 550 FPTN 410 056 R2
FPTN 410 056 R0002
0.080
N.C. + N.O.
1 1
R..63 ... 550
CA 12-1
FPTN 410 004 R0001
0.045
N.O. + N.O.
2 –
R..63 ... 550
CA 12-2
FPTN 410 005 R0001
0.045
2 x (N.C. + N.O.) 2 2
R..63 ... 550
CA 12-11
FPTN 410 013 R0001
0.090
(N.C. + N.O.)
3 1
R..63 ... 550
CA 12-12
FPTN 410 016 R0001
0.090
+ (N.O. + N.O.)
2 x (N.O. + N.O.) 4 –
R..63 ... 550
CA 12-22
FPTN 410 012 R0001
0.090
GB
F
1
2
3
1
2
3
Accessoires
Contacts auxiliaires (calibres 63 ... 550 A)
Contacts auxiliaires instantanés CA 12..
Ces blocs de contacts auxiliaires ne peuvent être montés que sur des contacteurs
de calibres < 550 A équipés d'un électro-aimant
R
,
RR
ou
RE
. Ils ne peuvent pas
être montés sur ceux équipés d'un électro-aimant
RC
.
Ils se fixent au-dessus de l'électro-aimant, sur un berceau support.
Les contacteurs équipés d'un électro-aimant type
R
ou
RE
peuvent recevoir 1 bloc
simple, 2 blocs simples, 3 blocs simples, ou 1 bloc 1 bloc double.
Ceux équipés d'un électro-aimant type
RR
peuvent recevoir seulement 1 ou 2
blocs simples.
Nombre maximal de blocs admissibles : >> "Accessoriabilité".
Procédure de montage :
>> "Entretien - Remplacement des contacts".
Références de commande
Bercau support
(selon calibre du contacteur)
Bloc simple
Bloc double
Contacts auxiliaires instantanés CA 15..
Il est également possible d'ajouter des contacts auxiliaires
CA 15..
sur les con-
tacteurs de calibres 63 ... 550 A dans l'espace éventuellement disponible sur le
châssis principal, en fonction de sa dimension et en respectant les distances de
montage requises. Nous consulter.
Accessories
Auxiliary Contacts (63 ... 550 A Ratings)
>> Auxiliary Contact Allocation ...................................................................................... page 10/5
>> Auxiliary Contact Mounting ...................................................................................... page 8/26,
>> Terminal Marking ........................................................................................................ page 6/22
Support bracket
(acc. to the contactor rating)
Single block
Double block
CA 12.. Instantaneous Auxiliary Contacts
These auxiliary contacts blocks can only be fitted to contactors rated < 550 A and
built with a
R
,
RR
or
RE
electromagnet. They cannot be mounted on contactors
built with a
RC
electromagnet.
They are mounted on a support bracket, above the electromagnet.
The contactors built with
R
or
RE
electromagnet can be equipped with 1 single
block, 2 single blocks, 3 single blocks, or 1 single block + 1 double block.
The contactors built with
RR
electromagnet can be equipped with 1 or 2 single
blocks only.
Maximum number of auxiliary contacts : >> "Auxiliary Contact Allocation".
Mounting Procedure:
>> "Maintenance - Auxiliary Contact Replacement".
Ordering Details
CA 15.. Instantaneous Auxiliary Contacts
It is also possible to add
CA 15..
auxiliary contacts on the contactors rated 63 ... 550 A
within the available space according to the contactor frame size.
Respect the clearing distances.
Please consult us.
Summary of Contents for 266M R Series
Page 1: ...GB F Instruction Handbook R Series Contactors Notice d instructions Contacteurs Série R ...
Page 2: ......
Page 48: ...7 2 1SBC104001M1701 7 GB F Notes Notes ...
Page 110: ...8 62 1SBC104001M1701 8 GB F ...
Page 124: ...10 10 8 1SBC104001M1701 GB F Notes Notes ...
Page 128: ...11 4 1SBC104001M1701 11 GB F Notes Notes ...