![ABB Robotics RobotWare 6 Applications Manual Download Page 50](http://html1.mh-extra.com/html/abb-robotics/robotware-6/robotware-6_applications-manual_450840050.webp)
7 The default deflection time is 0.1 mm. If the time it takes to build up the
deflection differ from this, type the correct value and tap
OK
.
xx1700002090
8 Tap
Save
to save the deflection values you have entered.
9 Tap
OK
to confirm the saving of the deflection parameters.
End the Tune Servo Gun routine
Tap
OK
to step out of the Tune Servo Gun routine.
xx1700002092
Continues on next page
50
Application manual - Servo Gun Setup
3HAC065014-001 Revision: E
© Copyright 2021 ABB. All rights reserved.
3 Servo Gun Setup wizard
3.2 Running the Servo Gun Setup wizard
Continued
Summary of Contents for RobotWare 6
Page 1: ...ROBOTICS Application manual Servo Gun Setup ...
Page 6: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 66: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 80: ......
Page 81: ......