Solares™ Smart Spa Bathing System Operating Manual
CD0036
- 29 -
1121
Reservoir Holding Tank Cleaning & Disinfecting Procedure
To minimize the likelihood of contamination or bio-film growth, the tank must be drained after the last
bath every night and allowed to dry. The door on the tub should be closed to prevent water spills when
draining the reservoir.
The tank must be visually inspected monthly to assure it remains clean. If hard water deposits develop
the tank should be cleaned wi
th Turbo Clean™ Pre
-Disinfectant Detergent. If biofilm or other residues
develop, the tank should be cleaned with Turbo Clean™ Pre
-Disinfectant Detergent and disinfected with
Cid-A-
L™ II Quaternary Disinfectant
.
To clean the reservoir tank, fill the bottom of the reservoir with about 5-6 inches of warm water. Add 7-
8 ounces of Turbo Clean™ Pre
-Disinfectant Detergent. Using a long-handled, soft-bristled brush, scrub
the inside of the tank with the cleaning mixture. When finished, drain the cleaning product from the
reservoir (with the tub door closed), and use the shower wand to rinse the inside of the tank.
To disinfect the reservoir tank, fill the bottom of the tank with 5-6 inches of water. Add 7-8 ounces of
Cid-A-
L™ II Quaternary Disinfectant. Scrub all i
nside surfaces with the disinfecting product. Keep the
tank surfaces wet with the mixture for at least 10 minutes. When finished, drain the cleaning product
from the reservoir (with the tub door closed), and use the shower wand to rinse the inside of the tank.
Allow the tank to dry.
When disinfecting in response to possible contamination by a specific pathogen, consult the Cid-A-L list
of pathogens for which it is effective. For disinfection with other antibacterial chemicals, consult with
your infection control specialist and the manufacturer’s direction for proper procedures and dilution
ratios.
Summary of Contents for Solares Smart Spa
Page 30: ......