background image

Integrated Access Controller  – Installation manual  

All rights reserved. © AAT HOLDING S.A.

 

 

14 

Programming codes table - standalone mode 

Parameter name 

or function

 

                Function code 
(after enter into programming mode) 

Programming mode

 

 

Enter programming mode 

*

 plus admin code PIN 

Exit the programming mode 

Basic parameters 

 

Controller initialization 

11 

Enabling alarm 
Disabling alarm 

121 
122

 

Tamper alarm 

13

 (

00

 disable 

01

 enable) 

Exit button input line parameters 

141 

(

01

 - type NO, 

00

 - type NC) 

142

 (

00

 disable 

01

 enable) 

Door magnet input line parameters 
Door open delay (unlock time) 
Door open time-out (after unlock time-out) 

151 

(

01

 - type NO, 

00

 - type NC) 

  

21

 (

00

 - 

99

) sec., 3 sec. default   

152

 (

00

 - 

99

) sec., 3 sec. default  

Alarm input line parameters 
Alarm action delay 
Alarm relay output 

161 

(

01

 - type NO, 

00

 - type NC) 

162

 (

00

 - 

99

) sec., 0 sec. default  

163 

(1

-RL1, 

2

-RL2, 

3

-RL1&2, 

4

–no out) 

Access mode setup

 

 

Card only 

221 

Card + PIN 

222 

PIN only 

223 

Card or PIN 

224 

User management

 

 

Add card continuously 

31 

Add single card 

32 

Add card + PIN continuously 

33 

Add single card + PIN 

34 

Add user with PIN continuously 

35 

Add single user with PIN  

36 

Delete single card 

37 

Delete all cards 

38 

Admin password setup (programming mode) 

41 

Threaten code setup 

42 

Notes: 

Default admin code 

000000

 must be change after first enter into programming 

mode for own using 

41

 command code. Leave default code allows unauthorized persons 

enter into programming mode and add own card. Reset admin password is available 
from KaDe Premium Plus software - > Controller setup -> Management password. New 

password should be download to the controller. 

Summary of Contents for KZ-1000-IP-U

Page 1: ...Installation Manual INTEGRATED ACCESS CONTROLLER KZ 1000 IP U KZ 1000 IP M VERSION 1 0...

Page 2: ...served AAT HOLDING S A 2 1 Introduction 3 2 Controller technical data 5 3 Controller wiring diagram 6 4 Controller installation 8 5 Management in standalone mode 9 6 Programming codes table 14 7 Manag...

Page 3: ...ontrol Recommended supply power type AWZ 200 plus 7Ah battery It s possibility to set one from four identification mode Card only default mode PIN only Card or PIN Card PIN KZ 1000 IP can work in stan...

Page 4: ...85 for connection with additional modules Supply Power connectors 12V 110 mA Lock control relay output Alarm relay output Bell control output from keypad key LED located on front panel upper left Blue...

Page 5: ...m Plus TCP For additional module connection RS485 Readers and Cards Integrated reader For UNIQUE card read range 5 15 cm U For MIFARE card red range 2 5 cm M External for two way control 26 bit Wiegan...

Page 6: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 6...

Page 7: ...UZ Blue Door contact SW Yellow Ground RD GND Black Exit button AN Purple PIR sensor input ALM Brown Ground RD GND GND RS485 port signal 485 Gray RS485 port signal 485 Orange 12V Red Controller supply...

Page 8: ...Integrated Access Controller Installation manual All rights reserved AAT HOLDING S A 8 Installation instruction...

Page 9: ...on is already stored card Five beeps card with this number is already added Optical indicator LED Blue LED Power on Green LED confirmation of the validity of the operation Orange LED flashing waiting...

Page 10: ...programming mode enter the code 13 then Code 00 when you want to disable the monitoring of the sensor code 01 to activate monitoring When a tamper alarm is activated an attempt to remove the unit from...

Page 11: ...lue from 00 to 99 seconds default 3 sec This is the time by which when a valid card or code is used the door will be unlocked After entering the programming mode enter the code identification mode 221...

Page 12: ...nter the PIN again Repeat the operation for subsequent reading cards with PIN codes After each added card reader generate a single beep Read the card will be cred ited automatically generated ID numbe...

Page 13: ...After adding a new administrator PIN code controller will generate a single beep and automatically exits the programming mode NOTE The default master code 000000 is mandatory to change after the firs...

Page 14: ...fault Alarm input line parameters Alarm action delay Alarm relay output 161 01 type NO 00 type NC 162 00 99 sec 0 sec default 163 1 RL1 2 RL2 3 RL1 2 4 no out Access mode setup Card only 221 Card PIN...

Page 15: ...ntroller must be installed within a protected space at a temperature of above 2 C and normal humidity Controllers in the system should be located so that the minimum distance from cables and high volt...

Page 16: ......