Installation and Maintenance Manual - Aastra 5000
AMT/PTD/PBX/0058/4/6/EN
Installation and activation
01/2011
Page
381
6.9
Upgrading an AXD in duplex configuration mode
To update a duplex AXD system proceed as follows:
•
Update the software of the active UCV-D card using the same procedure as for a
simplex configuration (see Section Updating the software of a simplex Aastra system
R5.1 to R5.2,
Important :
The procedure must be complete, the system restarted and the new version
validated (see Section Restarting and validating the new version).
From the menu
SYSTEM>CONFIGURATION>CARDS>Power supply > duplex
:
•
Disable the passive 10x CPU card.
•
Disable the passive 10x CPU card.
•
Check the passive card's downloading phase, message
"
passive Uc 1-0b
download"
.
•
At the end of the passive card downloading phase (20 minutes for a 1 GB compact
flash card and 30 minutes for a 2 GB card).
•
At the end of the downloading phase, the status of the passive card changes to active,
message
passive Uc 1-0b in service"
.
•
Also check the availability of the following message in the logbook. ,
Note : During update, the status of the RUCV-D card(s) changes to "IN ALARM".
6.10
Backing up and restoring the configuration
Backup and restore operations are performed from Aastra Management Portal. See
Aastra Management Portal operating manual.
6.11
Remote access modes
The user interface remote access modes are:
•
Access via an analogue modem
•
Access via an analogue ISDN modem
•
Access via an ISDN router.
14:38:47 02/07/08 2
*SERVICE: DUPLICATION IN SERVICE*
Summary of Contents for AXD
Page 16: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 16 01 2011...
Page 20: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 20 01 2011...
Page 22: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 22 01 2011...
Page 26: ...AMT PTD PBX 0058 4 6 EN Installation and Maintenance Manual Aastra 5000 Page 26 01 2011...